Abstract

Background and Aims: Fatty liver is the hepatic manifestation of obesity, but community‐based assessment of fatty liver among unselected patients is limited. We sought to determine the feasibility of and optimal protocol for quantifying fat content in the liver in the Framingham Heart Study using multidetector computed tomography (MDCT) scanning. Methods: Participants (n = 100, 49% women, mean age 59.4 years, mean body mass index 27.8 kg/m 2) were drawn from the Framingham Heart Study cohort. Two readers measured the attenuation of the liver, spleen, paraspinal muscles, and an external standard from MDCT scans using multiple slices in chest and abdominal scans. Results: The mean measurement variation was larger within a single axial computed tomography (CT) slice than between multiple axial CT slices for the liver and spleen, whereas it was similar for the paraspinal muscles. Measurement variation in the liver, spleen, and paraspinal muscles was smaller in the abdomen than in the chest. Three versus six measures of attenuation in the liver and two versus three measures in the spleen gave reproducible measurements of tissue attenuation (intraclass correlation coefficient [ICCC] of 1 in the abdomen). Intrareader and interreader reproducibility (ICCC) of the liver‐to‐spleen ratio was 0.98 and 0.99, the liver‐to‐phantom ratio was 0.99 and 0.99, and the liver‐to‐muscle ratio was 0.93 and 0.86, respectively. Conclusion: One cross‐sectional slice is adequate to capture the majority of variance of fat content in the liver per individual. Abdominal scan measures as compared to chest scan measures of fat content in the liver are more precise. The measurement of fat content in the liver on MDCT scans is feasible and reproducible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1746.2008.05420.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 132

Metadata

Authors
Speliotes, E. K., Massaro, J. M., Hoffmann, U., Foster, M. C., Sahani, D. V., Hirschhorn, J. N., O'Donnell, C. J., & Fox, C. S.
Venue
Journal of Gastroenterology and Hepatology
Publisher
Wiley
Published
2008-06
Volume
23
Issue
6
Pages
894-899
ISSN
  • 0815-9319 (ISSN-L)
  • 1440-1746
OpenAlex
W1967546867
Cited by
132
References
1
FWCI
3.50
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Liver fat is reproducibly measured using computed tomography in the Framingham Heart Study. https://app.cochat.ai/papers/10.1111/j.1440-1746.2008.05420.x
The paper
Speliotes, E. K., Massaro, J. M., Hoffmann, U., Foster, M. C., Sahani, D. V., Hirschhorn, J. N., O'Donnell, C. J., & Fox, C. S. (2008). Liver fat is reproducibly measured using computed tomography in the Framingham Heart Study. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2008.05420.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.