CoChat

Prospective comparative study of the EUS guided 25‐gauge FNA needle with the 19‐gauge Trucut needle and 22‐gauge FNA needle in patients with solid pancreatic masses

Sakamoto, Hiroki, Kitano, Masayuki, Komaki, Takamitsu, Noda, Kazu, Chikugo, Takaaki, Dote, Kensaku, Takeyama, Yoshifumi, Das, Kunal, Yamao, Kenji, Kudo, Masatoshi · 2009 · Journal of Gastroenterology and Hepatology
Cited by 226

The DOI matches its Crossref record.

Abstract

Background and Study Aims: The aim of this prospective study was to compare fine‐needle aspiration guided by endoscopic ultrasonography (EUS‐FNA) using 25‐gauge and 22‐gauge needles with the EUS‐guided 19‐gauge Trucut needle biopsy (EUS‐TNB) in patients with solid pancreatic mass. Patients and Methods: Twenty‐four consecutive patients with pancreatic mass underwent biopsies by both EUS‐FNA and EUS‐TNB. Three needles were compared with respect to technical success rate, tissue size obtained, overall diagnostic accuracy and accuracy for histological and cytological diagnosis. Results: The 25‐gauge EUS‐FNA was technically easier and obtained superior overall diagnostic accuracy than the 22‐gauge and Trucut needles, especially in lesions of the pancreas head and uncinate process. Overall accuracy for the 25‐gauge, 22‐gauge and Trucut needle was 91.7%, 79.7% and 54.1%, respectively. Accuracy for cytological diagnosis irrespective the site of lesions with 25‐gauge, 22‐gauge and Trucut needles was 91.7%, 75.0%, and 45.8%, respectively. For uncinate masses, it was 100%, 33.3%, and 0.0%, respectively. These differences were significant. Among technically successful patients, the accuracy for histological diagnosis using the 25‐gauge was significantly inferior (P < 0.05) to 22‐gauge and Trucut needles and the rates were 45.8%, 78.9% and 83.3%. Conclusions: The 25‐gauge FNA needle was significantly superior in terms of technical success rate and overall diagnostic accuracy, especially for the head and uncinate lesions, compared to the 22‐gauge and Trucut needles and could be considered ‘the best choice needle for cytological diagnosis’ of solid pancreatic lesions. If histological diagnosis is required, the 22‐gauge FNA needle and Trucut needle may be advantageous for use in head/uncinate and body/tail lesions, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1746.2008.05636.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Sakamoto, H., Kitano, M., Komaki, T., Noda, K., Chikugo, T., Dote, K., Takeyama, Y., Das, K., Yamao, K., & Kudo, M.
Venue
Journal of Gastroenterology and Hepatology
Publisher
Wiley
Published
2009-03
Volume
24
Issue
3
Pages
384-390
ISSN
  • 0815-9319 (ISSN-L)
  • 1440-1746
OpenAlex
W1973686537
Cited by
226
References
0
FWCI
4.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Prospective comparative study of the EUS guided 25‐gauge FNA needle with the 19‐gauge Trucut needle and 22‐gauge FNA needle in patients with solid pancreatic masses. https://app.cochat.ai/papers/10.1111/j.1440-1746.2008.05636.x
The paper
Sakamoto, H., Kitano, M., Komaki, T., Noda, K., Chikugo, T., Dote, K., Takeyama, Y., Das, K., Yamao, K., & Kudo, M. (2009). Prospective comparative study of the EUS guided 25‐gauge FNA needle with the 19‐gauge Trucut needle and 22‐gauge FNA needle in patients with solid pancreatic masses. Journal of Gastroenterology and Hepatology. https://doi.org/10.1111/j.1440-1746.2008.05636.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.