Review article: Luminex technology for HLA antibody detection in organ transplantation
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
SUMMARY: Since its inception in the early 1960s, the serologically based complement‐dependent cytotoxicity (CDC) assay has been the cornerstone technique for the detection of human leucocyte antigen (HLA) antibodies, not only in pre‐transplant renal patients, but also in other forms of organ transplantation. Recently, solid phase assays have been developed and introduced for this purpose, and in particular the Flow‐based bead assays such as the Luminex system. This latter assay has proved to be far more sensitive than the CDC assay and has revealed pre‐sensitization in potential transplant recipients not detected by other methods of HLA antibody detection. However, the clinical implications of this increased sensitivity have not been convincingly demonstrated until recently. This technology for HLA antibody detection permits the evaluation of the clinical importance of antibodies directed at, for example, HLA‐DPB1 and HLA‐DQA1, which has not been possible to date. There are Luminex issues, however, requiring resolution such as the ability to distinguish between complement fixing and non‐complement fixing antibodies and determination of their relative clinical significance. Luminex technology will permit a re‐evaluation of the role of HLA antibodies in both early and late antibody‐mediated rejection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microdroplet Assay of Human Serum Cytotoxins
TERASAKI, P. I., & McCLELLAND, J. D. (1964) · Nature · doi:10.1038/204998b0 · Cited by 2,060
Significance of the Positive Crossmatch Test in Kidney Transplantation
Patel, R., & Terasaki, P. I. (1969) · New England Journal of Medicine · doi:10.1056/nejm196904032801401 · Cited by 1,508
ANTI-HLA ANTIBODIES AFTER SOLID ORGAN TRANSPLANTATION1
McKenna, R. M., Takemoto, S. K., & Terasaki, P. I. (2000) · Transplantation · doi:10.1097/00007890-200002150-00001 · Cited by 382
Transplanting the Highly Sensitized Patient: The Emory Algorithm
Bray, R. A., Nolen, J. D. L., Larsen, C., Pearson, T., Newell, K. A., Kokko, K., Guasch, A., Tso, P., Mendel, J. B., & Gebel, H. M. (2006) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2006.01521.x · Cited by 216
Smith, J. D., Hamour, I. M., . Banner, N. R., & Rose, M. L. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2007.01991.x · Cited by 165 · cited 6×
“This may reflect on the sensitivity of the C4d assay in that some of the complement fixing antibodies were recorded as negative or a reflection of conversion to complement fixing antibodies in vivo.28 Smith et al.19 demonstrated similar results to Wahrmann et al. in 565 cardiac transplant recipients.”
MethodResultInfluentialJordan, S. C., Cunningham‐Rundles, C., & McEwan, R. N. (2003) · American Journal of Transplantation · doi:10.1034/j.1600-6143.2003.00121.x · Cited by 146 · cited 1×
“Previous economic analysis of these protocols confirms significant economic benefits and the additional cost of Luminex is small in comparison.(52) Performing Flow Cytometry antibody screening rather than serological screening for wait listed patients has been shown to be cost-effective with a gain in life years, tran…”
ResultHLA Antibody Identification With Single Antigen Beads Compared To Conventional Methods
El-Awar, N. R., Lee, J., & Terasaki, P. I. (2005) · Human Immunology · doi:10.1016/j.humimm.2005.07.005 · Cited by 130 · cited 2×
“SAG allows complex sera reacting with many HLA molecules to be dissected and accurate antibody specificities assigned as described fully by El-Awar et al.29 Often these multiple reactions are directed at one or two epitopes which are shared across several HLA class1 or class 2 molecules.”
BackgroundPost-Transplant Anti-HLA Class II Antibodies as Risk Factor for Late Kidney Allograft Failure
Campos, É. F., Junior, H. T. S., Machado, P. G. P., Franco, M. S., Pestana, J. O. M., & Gerbase‐DeLima, M. (2006) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2006.01503.x · Cited by 124 · cited 1×
“While both HLA class 1 and class 2 antibodies are associated with early graft rejection,(30) there is evidence that HLA class 2 antibodies are more strongly associated with long-term chronic rejection.(31) Luminex SAG technology permits evaluation of HLA class 2 antibody in pre- and post-transplant patients with a hig…”
BackgroundGibney, E. M., Cagle, L. R., Freed, B. M., Warnell, S. E., Chan, L., & Wiseman, A. C. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl202 · Cited by 117 · cited 2×
“Gibney et al.(18) reported on 136 renal transplant patients tested by Luminex of whom 16 had pre-transplant antibodies defined as a CDC PRA >30%.”
BackgroundWorthington, J. E., Robson, A. J., Sheldon, S., Langton, A. K., & Martin, S. (2001) · Human Immunology · doi:10.1016/s0198-8859(01)00282-8 · Cited by 64
Detection of Antibodies to HLA-DP in Renal Transplant Recipients Using Single Antigen Beads
Qiu, J., Cai, J., Terasaki, P. I., El-Awar, N. R., & Lee, J.-H. (2005) · Transplantation · doi:10.1097/01.tp.0000181384.49832.3a · Cited by 62 · cited 2×
“Qiu et al.34 implicated DP humoral rejection by identifying DP antibodies in 5.1% of 138 patients with a functioning graft and 19.5% of 185 patients with a rejected graft.”
BackgroundInfluentialThe Economic Impact of End Stage Kidney Disease in Australia
Cass, A., Chadban, S. J., Craig, J. C., Howard, K., McDonald, S., Salkeld, G. P., & White, S. (2006) · Cited by 57
Immunoglobulin Class and Specificity of Lymphocytotoxic Antibodies After Kidney Transplantation
Marcén, R., Ting, A., Taylor, C. J., Miach, P. J., Chapman, J. R., & Morris, P. J. (1988) · Nephrology Dialysis Transplantation · doi:10.1093/oxfordjournals.ndt.a091759 · Cited by 14 · cited 1×
“However, there is no clear consensus on the role these antibodies may play in renal graft rejection.(24,25) As a result of the above differences, there is some difficulty in precisely determining the true difference in sensitivity of the two assays as no study has taken all these factors into account.”
Background
Cited by
Leng, Y., Sun, K., Chen, X., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00382a · Cited by 258
Hachem, R. R., Yusen, R. D., Meyers, B. F., Aloush, A. A., Mohanakumar, T., Patterson, G. A., & Trulock, E. P. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.05.006 · Cited by 235
Diagnosis of Parasitic Diseases: Old and New Approaches
Ndao, M. (2009) · Interdisciplinary Perspectives on Infectious Diseases · doi:10.1155/2009/278246 · Cited by 193
“Adapted to the study of parasites, the Luminex assay could identify multiple organisms or different genotypes of one particular organism during the same reaction utilizing very low volume.”
BackgroundInfluentialMontgomery, R. A., Tatapudi, V. S., Leffell, M. S., & Zachary, A. A. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0039-x · Cited by 171
Qiu, C., Wang, X., Batson, S. A., Wang, B., Casiano, C. A., Francia, G., & Zhang, J.-Y. (2023) · Cancers · doi:10.3390/cancers15164064 · Cited by 9
“Its ability to simultaneously measure multiple autoantibodies, coupled with high sensitivity, specificity, and cost-effectiveness, makes it a valuable tool in cancer research and clinical diagnostics [37].”
Metadata
- Authors
- TAIT, B. D., HUDSON, F., CANTWELL, L., BREWIN, G., HOLDSWORTH, R., BENNETT, G., & JOSE, M.
- Venue
- Nephrology
- Publisher
- Wiley
- Published
- 2009-03
- Volume
- 14
- Issue
- 2
- Pages
- 247-254
- ISSN
- 1320-5358 (ISSN-L)
- 1440-1797
- OpenAlex
- W2105172077
- Cited by
- 159
- References
- 13
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.