CoChat

Validation of Embletta portable diagnostic system for identifying patients with suspected obstructive sleep apnoea syndrome (OSAS)

NG, Susanna S.S., CHAN, Tat‐On, TO, Kin‐Wang, NGAI, Jenny, TUNG, Alvin, KO, Fanny W.S., HUI, David S.C. · 2010 · Respirology
Cited by 136

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Background and objectives: This study aimed to evaluate the diagnostic accuracy of Embletta portable diagnostic system (PDS, Medcare, Reykjavik, Iceland) for the screening of sleep apnoea in clinical practice. Methods: The Embletta PDS is a digital three‐channel recording device that measures airflow through a nasal cannula connected to a pressure transducer, oxygen saturation plus both respiratory and abdominal movements via built‐in effort and body position sensors. An AHI is determined based on recording time. Nocturnal polysomnography (Alice 4, Healthdyne, Atlanta, USA), with airflow measured by a nasal pressure transducer (PTAF2, Pro‐Tech, Woodinville, WA, USA)) and Embletta PDS recordings, was performed simultaneously in consecutive patients with suspected OSA syndrome. The PSG recordings were analysed manually by a blinded investigator. Results: Ninety subjects were recruited and 10 failed Embletta PDS studies due to measurement failure. Among the remaining 80 subjects, 63 were males. The mean age (SD) was 51.4 (11.9) years old, BMI 27.1(4.2) kg/m 2, neck circumference 38.6 (3.6) cm and Epworth Sleepiness Score 9.7 (5.3). The AHI obtained by the Embletta PDS correlated closely with that obtained by PSG (Pearson correlation, r = 0.979, P < 0.001). Comparison of AHI based on the Embletta PDS against the PSG demonstrated high sensitivity at AHI ≥ 5/h (sensitivity 0.924 and specificity 0.857) and high specificity at AHI ≥ 20/h (sensitivity 0.853 and specificity 0.957). Conclusions: The Embletta PDS is a highly sensitive and specific screening device in quantifying AHI when compared against PSG in patients with suspected OSA syndrome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1440-1843.2009.01697.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 136

Metadata

Authors
NG, S. S. S., CHAN, T., TO, K., NGAI, J., TUNG, A., KO, F. W. S., & HUI, D. S. C.
Venue
Respirology
Publisher
Wiley
Published
2010-01-26
Volume
15
Issue
2
Pages
336-342
ISSN
  • 1323-7799 (ISSN-L)
  • 1440-1843
OpenAlex
W2109416068
Cited by
136
References
5
FWCI
5.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of Embletta portable diagnostic system for identifying patients with suspected obstructive sleep apnoea syndrome (OSAS). https://app.cochat.ai/papers/10.1111/j.1440-1843.2009.01697.x
The paper
NG, S. S. S., CHAN, T., TO, K., NGAI, J., TUNG, A., KO, F. W. S., & HUI, D. S. C. (2010). Validation of Embletta portable diagnostic system for identifying patients with suspected obstructive sleep apnoea syndrome (OSAS). Respirology. https://doi.org/10.1111/j.1440-1843.2009.01697.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.