The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intracorneal ring segments in ectatic corneal disease – a review
Abstract
The purpose of this review is to collect and summarize all the scientific literature regarding the use of intracorneal ring segments (ICRS) in corneal ectatic disease. These implants, initially designed to correct myopia in normal eyes, are implanted in the deep corneal stroma with the aim of achieving modifications to the corneal curvature and subsequently refractive adjustments. Colin et al. in 2000 were the first to report the efficacy of these implants in reducing the refractive error and corneal steepening in keratoconus eyes. Two main types of ICRS have been developed and used for the treatment of ectatic corneal disease, different in profile and diameter of implantation: Intacs and Ferrara rings. Successful outcomes have been reported by several authors with these implants in keratoconic eyes using different nomograms. Besides keratoconus, ICRS have been also used successfully for the management of pellucid marginal degeneration and post‐laser in situ keratomileusis corneal ectasia. The implantation procedure may be performed today by two surgical techniques to create the corneal channels where implants are inserted: mechanical dissection using a manual semicircular dissector (mechanical‐assisted) and photodisruption of lamellar tissue using the femtosecond laser technology (femtosecond‐assisted). With both techniques, visual, refractive and topographic improvements have been observed, although higher incidence of intraoperative and postoperative complications have been reported with the mechanical procedure according to the evidence found in the peer‐reviewed literature. ICRS technology is a promising therapeutic option in corneal ectatic disease, avoiding corneal graft and allowing a visual and refractive rehabilitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233
Cited by
TFOS DEWS II iatrogenic report
Gomes, J. A. P., Azar, D. T., Baudouin, C., Efron, N., Hirayama, M., Horwath-Winter, J., Kim, T., Mehta, J. S., Messmer, E. M., Pepose, J. S., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.004 · Cited by 462
Metadata
- Authors
- Piñero, D. P., & Alio, J. L.
- Venue
- Clinical & Experimental Ophthalmology
- Publisher
- Wiley
- Published
- 2010-03
- Volume
- 38
- Issue
- 2
- Pages
- 154-167
- ISSN
- 1442-6404 (ISSN-L)
- 1442-9071
- OpenAlex
- W2157133969
- Cited by
- 211
- References
- 1
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracorneal ring segments in ectatic corneal disease – a review. https://app.cochat.ai/papers/10.1111/j.1442-9071.2010.02197.x
- The paper
- Piñero, D. P., & Alio, J. L. (2010). Intracorneal ring segments in ectatic corneal disease – a review. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/j.1442-9071.2010.02197.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.