BACKGROUND: To assess the techniques and materials used in intravitreal injections. DESIGN: Descriptive study realized at the Vision Institute of the Federal University of São Paulo, Brazil. SAMPLES: Different brands of needles and syringes, as well as enucleated porcine eyeballs. METHODS: The ultra-structures of commonly used needles were analysed by scanning electron microscope, and they were compared using different criteria, such as irregularities and debris from the lubrication process. The scleral incision was also assessed using needles of different brands and sizes. Accuracies in drug administration were studied by comparing the residual and delivered volume of needles and also by the analysis of reflux after intravitreal injections. MAIN OUTCOME MEASURES: Efficiency and quality of materials used in intravitreal injections. RESULTS: Ultra-structure analyses showed that all needles had different types of irregularities. Some photographs showed debris from the lubrication process, especially in BD needles. Scleral incision analysis showed a tendency of reducing the ocular damage with increasing gauge (P=0.024). The investigation of delivery accuracy showed that almost all needles underdosed the amount injected (P<0.05), and that the reflux could be minimized by tunnelled injections with thinner needles. CONCLUSION: Needles used in intravitreal injections possess many irregularities in their structures, which may cause different injection outcomes. Analyses of scleral incisions showed that the larger the needle gauge, the lesser the scleral damage and the risk of complications. Moreover, drug administration inaccuracies might be one of the causes for some unsuccessful attempts of treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1442-9071.2010.02447.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
De Stefano, V. S., Abechain, J. J., de Almeida, L. F., Verginassi, D. M., Rodrigues, E. B., Freymuller, E., Maia, M., Magalhaes, O., Nguyen, Q. D., & Farah, M. E.
Venue
Clinical & Experimental Ophthalmology
Publisher
Wiley
Published
2011-04
Volume
39
Issue
3
Pages
236-242
ISSN
1442-6404 (ISSN-L)
OpenAlex
W2105416863
Cited by
36
References
1
FWCI
1.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Experimental investigation of needles, syringes and techniques for intravitreal injections: Intravitreal injections: experimental study. https://app.cochat.ai/papers/10.1111/j.1442-9071.2010.02447.x
The paper
De Stefano, V. S., Abechain, J. J., de Almeida, L. F., Verginassi, D. M., Rodrigues, E. B., Freymuller, E., Maia, M., Magalhaes, O., Nguyen, Q. D., & Farah, M. E. (2011). Experimental investigation of needles, syringes and techniques for intravitreal injections: Intravitreal injections: experimental study. Clinical & Experimental Ophthalmology. https://doi.org/10.1111/j.1442-9071.2010.02447.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.