Holter monitoring in the diagnosis of stroke mechanism
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Background: Atrial fibrillation (AF), an important and treatable cause of ischaemic stroke, can occur as a sustained or a paroxysmal arrhythmia. Continuous cardiac rhythm monitoring (Holter monitoring) is often performed in stroke patients to identify paroxysmal AF, which is an indication for warfarin anticoagulation in this patient population. Aim: The aim of this study was to assess the clinical utility of Holter monitoring in detecting occult AF in patients with possible cardioembolic stroke. Methods: The medical records of ischaemic stroke patients consecutively hospitalized at a single academic centre during a one‐year period were reviewed. Data regarding patient demographics, stroke characteristics, electrocardiography and echocardiography results and duration and findings of Holter monitoring were abstracted. The primary outcome was yield of newly diagnosed AF on Holter monitoring. Results: Of 465 consecutive patients admitted with a diagnosis of new ischaemic stroke, 210 underwent Holter monitoring. The mean duration of monitoring was 22.8 ± 4.0 h. Previously undiscovered AF was identified in five cases (2.4%), all of which represented non‐rheumatic AF. In three cases, the Holter test was negative despite AF documented on an admission electrocardiogram. Conclusions: Holter monitoring can identify occult paroxysmal AF, assisting targeted secondary prevention in patients with new ischaemic stroke. However, the standard 24‐h duration of monitoring probably underestimates the prevalence of paroxysmal AF in this population. Prospective studies are indicated to evaluate the value of longer monitoring periods in stroke populations. (Intern Med J 2004; 34: 305−309)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405
Cited by
Global epidemiology of atrial fibrillation
Rahman, F., Kwan, G. F., & Benjamin, E. J. (2014) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2014.118 · Cited by 731
Sposato, L. A., Cipriano, L. E., Saposnik, G., Vargas, E. R., Riccio, P. M., & Hachinski, V. (2015) · The Lancet Neurology · doi:10.1016/s1474-4422(15)70027-x · Cited by 694
Kishore, A., Vail, A., Majid, A., Dawson, J., Lees, K. R., Tyrrell, P. J., & Smith, C. J. (2014) · Stroke · doi:10.1161/strokeaha.113.003433 · Cited by 374
Liao, J., Khalid, Z., Scallan, C., Morillo, C., & O’Donnell, M. (2007) · Stroke · doi:10.1161/strokeaha.106.478685 · Cited by 331
Seet, R. C. S., Friedman, P. A., & Rabinstein, A. A. (2011) · Circulation · doi:10.1161/circulationaha.111.029801 · Cited by 276
Metadata
- Authors
- Shafqat, S., Kelly, P. J., & Furie, K. L.
- Venue
- Internal Medicine Journal
- Publisher
- Wiley
- Published
- 2004-06
- Volume
- 34
- Issue
- 6
- Pages
- 305-309
- ISSN
- 1444-0903 (ISSN-L)
- 1445-5994
- OpenAlex
- W2109140044
- Cited by
- 61
- References
- 1
- FWCI
- 0.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holter monitoring in the diagnosis of stroke mechanism. https://app.cochat.ai/papers/10.1111/j.1444-0903.2004.00589.x
- The paper
- Shafqat, S., Kelly, P. J., & Furie, K. L. (2004). Holter monitoring in the diagnosis of stroke mechanism. Internal Medicine Journal. https://doi.org/10.1111/j.1444-0903.2004.00589.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.