Clinical colour vision tests
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
The structure and function of the available and significant clinical colour vision tests are reviewed in the light of the needs in the clinical examination of congenital and acquired colour vision deficiencies. The tests are grouped and described as pseudo-isochromatic plates, arrangement tests, matching tests and vocational tests. The colorimetric constructions of the test types are described and the efficiency of their performance and usefulness discussed. Recommendations are made for basic and extended test batteries, when examining of congenital and acquired colour vision deficiencies in the consulting room.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90318-p · Cited by 5,737
Spectral sensitivity of the foveal cone photopigments between 400 and 500 nm
Smith, V. C., & Pokorny, J. (1975) · Vision Research · doi:10.1016/0042-6989(75)90203-5 · Cited by 1,318
The Farnsworth-Munsell 100-Hue and Dichotomous Tests for Color Vision*
Farnsworth, D. (1943) · Journal of the Optical Society of America · doi:10.1364/josa.33.000568 · Cited by 568
Edridge-Green, F. W. (1934) · BMJ · doi:10.1136/bmj.2.3856.1020-a · Cited by 441
Congenital and Acquired Color Vision Defects
Alvin, E., & Enoch, J. M. (1980) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)74880-9 · Cited by 352
A New Assessment of the Normal Ranges of the Farnsworth-Munsell 100-Hue Test Scores
Verriest, G., Laethem, J. V., & Uvijls, A. (1982) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)77380-5 · Cited by 291
The Characteristics of Tritanopia
Wright, W. D. (1952) · Journal of the Optical Society of America · doi:10.1364/josa.42.000509 · Cited by 270
Kinnear, P. R. (2002) · British Journal of Ophthalmology · doi:10.1136/bjo.86.12.1408 · Cited by 223
A METHOD FOR QUANTITATIVE SCORING OF THE FARNSWORTH PANEL D‐15
BOWMAN, K. J. (1982) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1982.tb00621.x · Cited by 216
Diagnosis of Defective Colour Vision
Vingrya, A. (1994) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.1994.tb02381.x · Cited by 198
John Dalton's Colour Vision Legacy
REGAN, B. (1998) · British Journal of Ophthalmology · doi:10.1136/bjo.82.2.203d · Cited by 181
Efficiency of the Ishihara test for identifying red-green colour deficiency
Birch, J. (1997) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.1997.tb00072.x · Cited by 170
Color-Axis Determination on the Farnsworth-Munsell 100-Hue Test
Smith, V. C., Pokorny, J., & Pass, A. S. (1985) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75002-0 · Cited by 170
The handicap of abnormal colour vision
Cole, B. L. (2004) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2004.tb05056.x · Cited by 165
Efficiency of the Ishihara test for identifying red-green colour deficiency
Birch, J. (1997) · Ophthalmic and Physiological Optics · doi:10.1046/j.1475-1313.1997.97000227.x · Cited by 147
Hardy, L. H., Rand, G., & Rittler, M. C. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000509 · Cited by 94
Evaluation of an updated HRR color vision test
BAILEY, J. E., Neitz, M., Tait, D. M., & Neitz, J. (2004) · Visual Neuroscience · doi:10.1017/s0952523804213463 · Cited by 92
Theory and practice of colour vision testing: A review Part 1
Lakowski, R. (1969) · Occupational and Environmental Medicine · doi:10.1136/oem.26.3.173 · Cited by 86
Belcher, S., Greenshields, K. W., & Wright, W. D. (1958) · British Journal of Ophthalmology · doi:10.1136/bjo.42.6.355 · Cited by 70
Quantitative Diagnosis of Defective Color Vision
Cronem, R. A. (1961) · American Journal of Ophthalmology · doi:10.1016/0002-9394(61)91952-3 · Cited by 45
HOW GOOD IS THE H-R-R TEST FOR COLOR BLINDNESS?
Walls, G. L. (1959) · Optometry and Vision Science · doi:10.1097/00006324-195904000-00001 · Cited by 38
Colour Vision Requirements of Firefighters
Margrain, T. H., Birch, J., & Owen, C. G. (1996) · Occupational Medicine · doi:10.1093/occmed/46.2.114 · Cited by 33
Estévez, O., Spekreijse, H., Dalen, J., & Lunel, H. F. E. V. (1983) · Optometry and Vision Science · doi:10.1097/00006324-198311000-00004 · Cited by 28
Colorimetric analysis of four editions of the Hardy-Rand-Rittler pseudoisochromatic tests
Dain, S. J. (2004) · Visual Neuroscience · doi:10.1017/s0952523804213475 · Cited by 25
Self-citationAn Evaluation of the AO H-R-R Pseudoisochromatic Plates
Rand, G. (1956) · A M A Archives of Ophthalmology · doi:10.1001/archopht.1956.00930040744013 · Cited by 21
Cole, B. L., & Vingrys, A. J. (1983) · Documenta Ophthalmologica · doi:10.1007/bf00140807 · Cited by 20
The C‐100:a new dichotomiser of colour vision defectives
Metha, A. B., & Vingrys, A. J. (1992) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.1992.tb00615.x · Cited by 19
Colour vision in normal subjects tested by the colour arrangement test ‘Roth 28-hue desaturated’
Erb, C., Adler, M., Stübiger, N., Wohlrab, M., Zrenner, E., & Thiel, H.-J. (1998) · Vision Research · doi:10.1016/s0042-6989(97)00433-1 · Cited by 18
Can clinical colour vision tests be used to predict the results of the Farnsworth lantern test?
Cole, B. L., & Maddocks, J. D. (1998) · Vision Research · doi:10.1016/s0042-6989(98)00119-9 · Cited by 17
MISUSE OF THE ISHIHARA TEST FOR COLOUR BLINDNESS.
Cole, B. L. (1996) · PubMed · Cited by 16
Validity of the Holmes–Wright lantern as a color vision test for the rail industry
Hovis, J. K., & Oliphant, D. (1998) · Vision Research · doi:10.1016/s0042-6989(98)00054-6 · Cited by 14
Analysis of Variance in Anomaloscope Matches
Moreland, J. D. (1984) · Documenta ophthalmologica. Proceedings series · doi:10.1007/978-94-009-6551-5_11 · Cited by 12
A Clinical Evaluation of the ‘Oscar’ Color Vision Set
Cavonius, C. R., & Kammann, J. (1984) · Documenta ophthalmologica. Proceedings series · doi:10.1007/978-94-009-6551-5_33 · Cited by 10
Birch, J. (1999) · PubMed · Cited by 9
Verriest, G., & Uvijls, A. (1987) · Documenta ophthalmologica. Proceedings series · doi:10.1007/978-94-009-4275-2_27 · Cited by 6
Cited by
Acquired color vision deficiency
Simunovic, M. P. (2016) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2015.11.004 · Cited by 176
Assessment of inherited colour vision defects in clinical practice
Cole, B. L. (2007) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2007.00135.x · Cited by 116
Metadata
- Authors
- Dain, S. J.
- Venue
- Clinical and Experimental Optometry
- Publisher
- Informa UK Limited
- Published
- 2004-07-01
- Volume
- 87
- Issue
- 4-5
- Pages
- 276-293
- ISSN
- 0816-4622 (ISSN-L)
- 1444-0938
- OpenAlex
- W1984246043
- Cited by
- 187
- References
- 35
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.