CoChat

Comparison of different near‐infrared spectroscopic cerebral oxygenation indices with central venous and jugular venous oxygenation saturation in children

NAGDYMAN, NICOLE, EWERT, PETER, PETERS, BJÖRN, MIERA, OLIVER, FLECK, THILO, BERGER, FELIX · 2008 · Pediatric Anesthesia
Cited by 116

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Summary: Background: We compared two different near‐infrared spectrophotometers: cerebral tissue oxygenation index (TOI) measured by NIRO 200 and regional cerebral oxygenation index (rSO 2 ) measured by INVOS 5100 with venous oxygen saturation in the jugular bulb (SjO 2 ) and central SvO 2 from the superior caval vein (SVC) during elective cardiac catheterization in children. Methods: A prospective observational clinical study in 31 children with congenital heart defects in a catheterization laboratory was undertaken. TOI was compared with SjO 2 in the left jugular bulb and with SvO 2 . rSO 2 was compared with SjO 2 from the right jugular bulb and SvO 2 . Linear regression analysis and Pearson’s correlation coefficient were calculated and Bland–Altman analyses were performed. Results: Cerebral TOI and SjO 2 were significantly correlated ( r = 0.56, P < 0.0001), as well as TOI and SvO 2 with r = 0.74 ( P < 0.0001). Bland–Altman plots showed a mean bias of −4.3% with limits of agreement of 15.7% and −24.3% for TOI and SjO 2 and a mean bias of −4.9% with limits of agreement of 10.3% and −20.1% for TOI and SvO 2 . Cerebral rSO 2 and SjO 2 showed a significant correlation ( r = 0.83, P < 0.0001) and rSO 2 and SvO 2 showed excellent correlation with r = 0.93 ( P < 0.0001). Bland–Altman plots showed a mean bias of −5.2% with limits of agreement of between 8.4% and −18.8% for rSO 2 and SjO 2 and a mean bias of 5.6% with limits of agreement of 13.4% and −2.2% for rSO 2 and SvO 2 . Conclusions: Both near‐infrared spectroscopy devices demonstrate a significant correlation with SjO 2 and SvO 2 values; nevertheless both devices demonstrate a substantial bias of the measurements to both SjO 2 and SvO 2 .

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1460-9592.2007.02365.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 116

Metadata

Authors
NAGDYMAN, N., EWERT, P., PETERS, B., MIERA, O., FLECK, T., & BERGER, F.
Venue
Pediatric Anesthesia
Publisher
Wiley
Published
2007-10-17
Volume
18
Issue
2
Pages
160-166
ISSN
  • 1155-5645 (ISSN-L)
  • 1460-9592
OpenAlex
W2069980876
Cited by
116
References
2
FWCI
5.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.