Ultrasound guidance allows faster peripheral IV cannulation in children under 3 years of age with difficult venous access: a prospective randomized study
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Summary: Objectives: Ultrasound‐guided peripheral venous access (USG‐PIVA) presents many advantages over the reference ‘blind’ technique in both adults and children in emergency situations. Aim: To compare USG‐PIVA with the blind technique in children <3 years undergoing general anesthesia. Methods: After obtaining the approval of the ethics committee and informed consent from the parents, we included all children <3 years scheduled to undergo general anesthesia [surgery, magnetic resonance imaging (MRI)], who presented difficult venous access. The children were randomized into two groups: the US group (USG‐PIVA) and the B group (blind). The primary endpoint was time to cannulation (from tourniquet placement to successful IV cannulation), compared between USG‐PIVA group and B group by intention‐to‐treat analysis. Secondary outcomes were success rate at the first puncture, number of punctures, and diameter of the catheters. Cannulations requiring >15 min were considered as failures. In case of failure in group B, USG‐PIVA was attempted for a further 15 min. Results: Twenty children were included in each group. Groups were comparable for sex, age, and BMI. Significant differences were observed in median time to cannulation (63.5 s vs 420.5 s, USG‐PIVA vs B respectively, P < 0.001); median number of punctures (1 vs 2.5, USG‐PIVA vs B, P = 0.004); and success rate at first cannulation (85% vs 35%, USG‐PIVA vs B, P = 0.0012). In contrast, overall success rate did not differ significantly between groups (90% vs 85%, USG‐PIVA vs B, P = 0.63). Conclusions: Ultrasound‐guided peripheral venous access leads to faster peripheral IV access and should therefore be recommended in children presenting with difficult venous access.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Costantino, T. G., Parikh, A. K., Satz, W. A., & Fojtik, J. P. (2005) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2004.12.026 · Cited by 435
Ultrasound-guidance vs. standard technique in difficult vascular access patients by ed technicians
Bauman, M., Braude, D., & Crandall, C. (2009) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2008.02.005 · Cited by 160
Cited by
Cooke, M., Ullman, A. J., Ray-Barruel, G., Wallis, M., Corley, A., & Rickard, C. M. (2018) · PLOS ONE · doi:10.1371/journal.pone.0193436 · Cited by 233
Ultrasound-guided peripheral venous access: A meta-analysis and systematic review
Stolz, L. A., Stolz, U., Howe, C., Farrell, I. J., & Adhikari, S. (2015) · The Journal of Vascular Access · doi:10.5301/jva.5000346 · Cited by 189
Poulsen, E., Aagaard, R., Bisgaard, J., Sørensen, H. T., & Juhl-Olsen, P. (2023) · European Journal of Emergency Medicine · doi:10.1097/mej.0000000000000993 · Cited by 30
Hosseini, S. J., Firooz, M., Yazdi, K., Abdollahi, M., Hosseini, S. R., & Ramezani, M. (2025) · The Journal of Vascular Access · doi:10.1177/11297298241259843 · Cited by 6
Metadata
- Authors
- Benkhadra, M., Collignon, M., Fournel, I., Oeuvrard, C., Rollin, P., Perrin, M., Volot, F., & Girard, C.
- Venue
- Pediatric Anesthesia
- Publisher
- Wiley
- Published
- 2012-03-12
- Volume
- 22
- Issue
- 5
- Pages
- 449-454
- ISSN
- 1155-5645 (ISSN-L)
- 1460-9592
- OpenAlex
- W1544946872
- Cited by
- 131
- References
- 2
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.