The usage of a simplified self‐titration dosing guideline (303 Algorithm) for insulin detemir in patients with type 2 diabetes – results of the randomized, controlled PREDICTIVE™ 303 study
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The Predictable Results and Experience in Diabetes through Intensification and Control to Target: An International Variability Evaluation 303 (PREDICTIVE™ 303) Study (n = 5604) evaluated the effectiveness of insulin detemir, a long‐acting basal insulin analogue, using a simplified patient self‐adjusted dosing algorithm (303 Algorithm group) compared with standard‐of‐care physician‐driven adjustments (Standard‐of‐care group) in a predominantly primary care setting, over a period of 6 months. Insulin detemir was to be started once‐daily as add‐on therapy to any other glucose‐lowering regimens or as a replacement of prestudy basal insulin in patients with type 2 diabetes. Investigator sites rather than individual patients were randomized to either the 303 Algorithm group or the Standard‐of‐care group. Patients from the 303 Algorithm group sites were instructed to adjust their insulin detemir dose every 3 days based on the mean of three ‘adjusted’ fasting plasma glucose (aFPG) values (capillary blood glucose calibrated to equivalent plasma glucose values) using a simple algorithm: mean aFPG < 80 mg/dl (<4.4 mmol/l), reduce dose by 3 U; aFPG between 80 and 110 mg/dl (4.4–6.1 mmol/l), no change; and aFPG > 110 mg/dl (>1.1 mmol/l), increase dose by 3 U. The insulin detemir dose for patients in the Standard‐of‐care group was adjusted by the investigator according to the standard of care. Mean A1C decreased from 8.5% at baseline to 7.9% at 26 weeks for the 303 Algorithm group and from 8.5 to 8.0% for the Standard‐of‐care group (p = 0.0106 for difference in A1C reduction between the two groups). Mean FPG values decreased from 175 mg/dl (9.7 mmol/l) at baseline to 141 mg/dl (7.8 mmol/l) for the 303 Algorithm group and decreased from 174 mg/dl (9.7 mmol/l) to 152 mg/dl (8.4 mmol/l) for the Standard‐of‐care group (p < 0.0001 for difference in FPG reduction between the two groups). Mean body weight remained the same at 26 weeks in both groups (change from baseline 0.1 and −0.2 kg for the 303 Algorithm group and the Standard‐of‐care group respectively). At 26 weeks, 91% of the patients in the 303 Algorithm group and 85% of the patients in the Standard‐of‐care group remained on once‐daily insulin detemir administration. The rates of overall hypoglycaemia (events/patient/year) decreased significantly from baseline in both groups [from 9.05 to 6.44 for the 303 Algorithm group (p = 0.0039) and from 9.53 to 4.95 for the Standard‐of‐care group (p < 0.0001)]. Major hypoglycaemic events were rare in both groups (0.26 events/patient/year for the 303 Algorithm group and 0.20 events/patient/year for the Standard‐of‐care group; p = 0.2395). In conclusion, patients in the 303 Algorithm group achieved comparable glycaemic control with higher rate of hypoglycaemia as compared with patients in the Standard‐of‐care group, possibly because of more aggressive insulin dose adjustments. The vast majority of the patients in both groups were effectively treated with once‐daily insulin detemir therapy. The use of insulin detemir in this predominantly primary care setting achieved significant improvements in glycaemic control with minimal risk of hypoglycaemia and no weight gain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pearson, T. A., Mensah, G. A., Alexander, R. W., Anderson, J. L., Cannon, R. O., Criqui, M., Fadl, Y. Y., Fortmann, S. P., Hong, Y., Myers, G. L., et al. (2003) · Circulation · doi:10.1161/01.cir.0000052939.59093.45 · Cited by 6,401
Danesh, J., Wheeler, J. G., Hirschfield, G. M., Eda, S., Eiriksdottir, G., Rumley, A., Lowe, G. D. O., Pepys, M. B., & Gudnason, V. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032804 · Cited by 2,953
Standards of Medical Care in Diabetes—2007
American Diabetes Association (2007) · Diabetes Care · doi:10.2337/dc07-s004 · Cited by 1,190
Hermansen, K., Davies, M., Derezinski, T., Martinez Ravn, G., Clauson, P., Home, P., & on behalf of the Levemir Treat-to-Target Study Group (2006) · Diabetes Care · doi:10.2337/dc05-1365 · Cited by 627
Heise, T., Nosek, L., Rønn, B. B., Endahl, L., Heinemann, L., Kapitza, C., & Draeger, E. (2004) · Diabetes · doi:10.2337/diabetes.53.6.1614 · Cited by 614
Hermansen, K., Fontaine, P., Kukolja, K. K., Peterkova, V., Leth, G., & Gall, M.-A. (2004) · Diabetologia · doi:10.1007/s00125-004-1365-z · Cited by 365
Weight Gain Associated With Intensive Therapy in the Diabetes Control and Complications Trial
The DCCT Research Group (1988) · Diabetes Care · doi:10.2337/diacare.11.7.567 · Cited by 345
Improvement of Glycemic Control in Subjects With Poorly Controlled Type 2 Diabetes
Davies, M., Storms, F., Shutler, S., Bianchi-Biscay, M., Gomis, R., & for the AT.LANTUS Study Group (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1282 · Cited by 314
Vague, P., Selam, J.-L., Skeie, S., De Leeuw, I., Elte, J. W. F., Haahr, H., Kristensen, A., & Draeger, E. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.590 · Cited by 294
Self-citationKlein, O., Lynge, J., Endahl, L., Damholt, B., Nosek, L., & Heise, T. (2007) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2006.00685.x · Cited by 251
Russell-Jones, D., Simpson, R., Hylleberg, B., Draeger, E., & Bolinder, J. (2004) · Clinical Therapeutics · doi:10.1016/s0149-2918(04)90072-0 · Cited by 194
Cited by
Interpretation and Impact of Real-World Clinical Data for the Practicing Clinician
Blonde, L., Khunti, K., Harris, S. B., Meizinger, C., & Skolnik, N. S. (2018) · Advances in Therapy · doi:10.1007/s12325-018-0805-y · Cited by 714
Handelsman, Y., Mechanick, J. I., Blonde, L., Grunberger, G., Bloomgarden, Z. T., Bray, G. A., Dagogo-Jack, S., Davidson, J. A., Einhorn, D., Ganda, O., et al. (2011) · Endocrine Practice · doi:10.4158/ep.17.s2.1 · Cited by 513
Blonde, L., Merilainen, M., Karwe, V., Raskin, P., & TITRATE™ Study Group (2009) · Diabetes, Obesity and Metabolism · doi:10.1111/j.1463-1326.2009.01060.x · Cited by 180
Hsu, W. C., Lau, K. H. K., Huang, R., Ghiloni, S., Le, H., Gilroy, S., Abrahamson, M., & Moore, J. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0160 · Cited by 135
Arnolds, S., Kuglin, B., Kapitza, C., & Heise, T. (2010) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2010.02470.x · Cited by 69
Metadata
- Authors
- Meneghini, L., Koenen, C., Weng, W., & Selam, J. ‐.
- Venue
- Diabetes, Obesity and Metabolism
- Publisher
- Wiley
- Published
- 2007-10-07
- Volume
- 9
- Issue
- 6
- Pages
- 902-913
- ISSN
- 1462-8902 (ISSN-L)
- 1463-1326
- OpenAlex
- W2000224320
- Cited by
- 127
- References
- 11
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.