CoChat

Comparison of Continuous Subcutaneous Insulin Infusion with Multiple Insulin Injections Using the NovoPen

Saurbrey, N., Arnold‐Larsen, S., Møller‐Jensen, B., Kühl, C. · 1988 · Diabetic Medicine
Cited by 37

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Twenty‐one patients with insulin‐dependent diabetes mellitus (IDDM) participated in a 20‐week randomized cross‐over comparison of continuous subcutaneous insulin infusion (CSII) with intensified conventional treatment (ICT) using the NovoPen, The Medix or the Auto‐Syringe pumps were used for CSII and, during ICT with NovoPen, conventional plastic syringes were used for injections of intermediate‐acting insulin at bedtime. At entry HbA 10 was 8.7±0.4% (mean ±SE) in CSII patients and 8.8±0.5% in the ICF group. HbA 10 declined significantly in both groups (ICT 7.6±0.2%; CSII 7.6±0.2%) though there was no significant difference between the responses. Overall mean blood glucose was slightly but significantly lower during CSII than during ICT (CSII: 7.6±0.2 mmol/l; ICT: 8.7±0.4 mmol/l, p<0.05). The number of hypoglycaemic episodes did not differ significantly between patients treated with NovoPen and CSII. At the end of the study, a questionnaire revealed that all but one patient preferred ICT with NovoPen to conventional therapy. Given the choice for future treatment, 6 patients chose CSII, 12 patients preferred ICT with NovoPen and 1 was unsure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1988.tb00962.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 37

Metadata

Authors
Saurbrey, N., Arnold‐Larsen, S., Møller‐Jensen, B., & Kühl, C.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1988-03
Volume
5
Issue
2
Pages
150-153
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2122097636
Cited by
37
References
2
FWCI
1.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Continuous Subcutaneous Insulin Infusion with Multiple Insulin Injections Using the NovoPen. https://app.cochat.ai/papers/10.1111/j.1464-5491.1988.tb00962.x
The paper
Saurbrey, N., Arnold‐Larsen, S., Møller‐Jensen, B., & Kühl, C. (1988). Comparison of Continuous Subcutaneous Insulin Infusion with Multiple Insulin Injections Using the NovoPen. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.1988.tb00962.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.