Home Glucose Monitoring in Type 2 Diabetes: Is It a Waste of Time?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A cross‐sectional study to assess home glucose monitoring practices was conducted in 200 non‐insulin‐treated diabetic patients consecutively attending our hospital clinic. Of the 200, 97 (48 %) patients (Group 1) regularly monitored urine (n = 74), blood (n = 19) or both (n = 4); 103 (52 %) patients (Group 2) performed no home monitoring. The two groups were similar in terms of age, sex, duration of diabetes and type of treatment. The prevalence of diabetic complications was also closely comparable and only peripheral neuropathy differed between the groups, being more common in Group 1 (n = 12) than Group 2 (n = 4); p < 0.05. There was also no significant difference between the HbA 1 concentration (mean ± SD) in Group 1 (9.7 ± 2.2 %) and Group 2 (9.4 ± 2.0 %). The mean frequency of home monitoring was four tests weekly, but only 21 (22 %) kept a written record and 60 (62 %) would never alter their treatment on the basis of their results. Almost a third of patients could not interpret the results of monitoring or give the normal range of values. Home glucose monitoring, particularly of urine, is widely practised in Type 2 diabetes, at considerable overall expense. However, convincing evidence of its value in helping patients improve their blood glucose control or preventing the complications of the disease is lacking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pirart, J. (1978) · Diabetes Care · doi:10.2337/diacare.1.3.168 · Cited by 1,290
Cited by
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595
Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287
“Currently, a moderate use of SMBG is recommended in these patients and some authors conclude that the high costs of SMBG in these patients are not justified and that SMBG is a waste of time and money [9, 15, 16].”
BackgroundEvans, J. M. M., Newton, R. W., Ruta, D. A., MacDonald, T. M., Stevenson, R. J., & Morris, A. D. (1999) · BMJ · doi:10.1136/bmj.319.7202.83 · Cited by 283
Metadata
- Authors
- Patrick, A. W., Gill, G. V., MacFarlane, I. A., Cullen, A., Power, E., & Wallymahmed, M.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 1994-01-02
- Volume
- 11
- Issue
- 1
- Pages
- 62-65
- ISSN
- 0742-3071 (ISSN-L)
- 1464-5491
- OpenAlex
- W1974106167
- Cited by
- 54
- References
- 1
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.