Implementation of an Active Mass Driver Using Acceleration Feedback Control
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Most of the current research on active structural control for aseismic protection has focused on either full‐state feedback strategies or velocity‐feedback strategies. However, accurate measurement of the necessary displacements and velocities of the structure is difficult to achieve directly, particularly during seismic activity. Because accelerometers are inexpensive and can readily provide reliable measurement of the structural accelerations at strategic points on the structure, development of control methods based on acceleration feedback is an ideal solution to this problem. Recent studies of active bracing and active tendon systems have shown that H 2 /LQG frequency domain control methods employing acceleration feedback can be used effectively for aseismic protection of structures. This paper demonstrates experimentally the efficacy of acceleration‐feedback–based active mass driver (AMD) systems in reducing the response of seismically excited structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Cited by
Modeling and control of magnetorheological dampers for seismic response reduction
Dyke, S. J., Spencer, B. F., Sain, M. K., & Carlson, J. D. (1996) · Smart Materials and Structures · doi:10.1088/0964-1726/5/5/006 · Cited by 1,341
Self-citationSemiactive Control Strategies for MR Dampers: Comparative Study
Jansen, L. M., & Dyke, S. J. (2000) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2000)126:8(795 · Cited by 614
Self-citationControlling buildings: a new frontier in feedback
(1997) · IEEE Control Systems · doi:10.1109/37.642972 · Cited by 445
Passive structural control of offshore wind turbines
Lackner, M. A., & Rotea, M. A. (2011) · Wind Energy · doi:10.1002/we.426 · Cited by 378
Structural control of floating wind turbines
Lackner, M. A., & Rotea, M. A. (2011) · Mechatronics · doi:10.1016/j.mechatronics.2010.11.007 · Cited by 275
Metadata
- Authors
- Dyke, S. J., Spencer, B. F., Quast, P., Kaspari, D. C., & Sain, M. K.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 1996-09
- Volume
- 11
- Issue
- 5
- Pages
- 305-323
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W2167827845
- Cited by
- 144
- References
- 1
- FWCI
- 29.40
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of an Active Mass Driver Using Acceleration Feedback Control. https://app.cochat.ai/papers/10.1111/j.1467-8667.1996.tb00445.x
- The paper
- Dyke, S. J., Spencer, B. F., Quast, P., Kaspari, D. C., & Sain, M. K. (1996). Implementation of an Active Mass Driver Using Acceleration Feedback Control. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.1996.tb00445.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.