The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hybrid Control of Smart Structures Using a Novel Wavelet-Based Algorithm
Open accessAbstract
A tuned liquid column damper (TLCD) system provides the same level of vibration suppression as a conventional tuned mass damper (TMD) system but with several advantages. A new hybrid control system is presented through judicious combination of a passive supplementary damping system with a semi-active TLCD system. The new model utilizes the advantages of both passive and semi-active control systems, thereby improving the overall performance, reliability, and operability of the control system during normal operations as well as a power or computer failure. The robust wavelet-hybrid feedback least mean square (LMS) control algorithm developed recently by the authors is used to find optimal values of the control parameters. The effectiveness and robustness of the proposed hybrid damper-TLCD system in reducing the vibrations under various seismic excitations are evaluated through numerical simulations performed for an eight-story frame using three different simulated earthquake ground accelerations. It is found that the new model is effective in significantly reducing the response of the structure under various seismic excitations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance of Multiple Mass Dampers under Random Loading
Kareem, A., & Kline, S. (1995) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(1995)121:2(348) · Cited by 306 · cited 1×
“Another proposed solution is the multipleTMD (MTMD) system where more than one TMD system are designed and distributed within the structure to cover a range of dominant frequencies (Kareem and Kline, 1995).”
Background
Cited by
GHOSH-DASTIDAR, S., & ADELI, H. (2009) · International Journal of Neural Systems · doi:10.1142/s0129065709002002 · Cited by 1,057
Self-citationSignal Processing Techniques for Vibration-Based Health Monitoring of Smart Structures
Amezquita-Sanchez, J. P., & Adeli, H. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9135-7 · Cited by 487
Self-citationGutierrez Soto, M., & Adeli, H. (2013) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-013-9091-7 · Cited by 346
Self-citationRoad Crack Detection Using Visual Features Extracted by Gabor Filters
Zalama, E., Gómez‐García‐Bermejo, J., Medina, R., & Llamas, J. (2014) · Computer-Aided Civil and Infrastructure Engineering · doi:10.1111/mice.12042 · Cited by 303
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
Self-citation
Metadata
- Authors
- Kim, H., & Adeli, H.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 2005-01
- Volume
- 20
- Issue
- 1
- Pages
- 7-22
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W2019293132
- Cited by
- 121
- References
- 1
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid Control of Smart Structures Using a Novel Wavelet-Based Algorithm. https://app.cochat.ai/papers/10.1111/j.1467-8667.2005.00373.x
- The paper
- Kim, H., & Adeli, H. (2005). Hybrid Control of Smart Structures Using a Novel Wavelet-Based Algorithm. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.2005.00373.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.