Modal Flexibility Analysis of Cable‐Stayed Ting Kau Bridge for Damage Identification
Open accessThe DOI matches its Crossref record.
Abstract
The cable‐stayed Ting Kau Bridge has been permanently instrumented with more than 230 sensors for long‐term structural health monitoring. In this article, the feasibility of using the measured dynamic characteristics of the bridge for damage detection is studied. Making use of a validated three‐dimensional (3D) finite element model (FEM), modal flexibility matrices of the bridge are constructed using a few truncated modes and incomplete modal vectors at the sensor locations. The relative flexibility change (RFC) between intact and damage states is then formulated as an index to locate damage. The applicability of this flexibility index for damage location in the cable‐stayed bridge is examined by investigating various damage scenarios including those at stay cables, longitudinal stabilizing cables, bearings and supports, longitudinal girders and cross girders, and taking into account measurement noise in modal data. The influence of two ambient factors, that is, temperature change and traffic loading, on the damage detectability is also analyzed by approximately considering an equivalent alteration in the material and structural behaviors. It is revealed that in the absence of ambient effects the RFC index performs well for locating damage of different severities in single‐damage cases. In multi‐damage cases the RFC index may provide false‐negative identification for damage at the members with low sensitivity. Eliminating ambient effects is requisite for reliable detection of damage at stay cables and cross girders. The capability of the RFC index for locating damage at cross girders is significantly dropped in the presence of measurement noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optimization of sensor placement for structural health monitoring: a review
Ostachowicz, W., Soman, R., & Malinowski, P. (2019) · Structural Health Monitoring · doi:10.1177/1475921719825601 · Cited by 388
Smart structures: Part I—Active and semi-active control
Fisco, N. R., & Adeli, H. (2011) · Scientia Iranica · doi:10.1016/j.scient.2011.05.034 · Cited by 270
The state of the art in structural health monitoring of cable-stayed bridges
Li, H., & Ou, J. (2016) · Journal of Civil Structural Health Monitoring · doi:10.1007/s13349-015-0115-x · Cited by 267
Optimal sensor placement for damage detection of bridges subject to ship collision
Guo, Y. L., Ni, Y. Q., & Chen, S. K. (2017) · Structural Control and Health Monitoring · doi:10.1002/stc.1963 · Cited by 31
Self-citation
Metadata
- Authors
- Ni, Y. Q., Zhou, H. F., Chan, K. C., & Ko, J. M.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 2008-02-12
- Volume
- 23
- Issue
- 3
- Pages
- 223-236
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W2016616750
- Cited by
- 119
- References
- 0
- FWCI
- 24.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Modal Flexibility Analysis of Cable‐Stayed Ting Kau Bridge for Damage Identification. https://app.cochat.ai/papers/10.1111/j.1467-8667.2008.00521.x
- The paper
- Ni, Y. Q., Zhou, H. F., Chan, K. C., & Ko, J. M. (2008). Modal Flexibility Analysis of Cable‐Stayed Ting Kau Bridge for Damage Identification. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.2008.00521.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.