CoChat

Active and Semi‐active Adaptive Control for Undamaged and Damaged Building Structures Under Seismic Load

Open access
Bitaraf, Maryam, Hurlebaus, Stefan, Barroso, Luciana R. · 2012 · Computer-Aided Civil and Infrastructure Engineering
Cited by 95

The DOI matches its Crossref record.

Abstract

During the lifetime of a structural system, many severe events such as earthquakes and strong winds may impact the system and result in potential damage. To mitigate the structural vibration and damage during these extreme events, control devices such as active and semi‐active devices have received considerable attention because of their attractive characteristics. Active control devices are adaptable to any change and semi‐active devices have the capability of offering the reliability of passive devices and the versatility and adaptability of active devices. In this research, a direct‐adaptive‐control method is used to control the behavior of an undamaged and a damaged structure using semi‐active and active devices. In the adaptive control method, the controlled system is forced to behave like the model system which exhibits the desired behavior. The model of the adaptive control method is defined in a way to optimize the response of the controlled structure. The controller developed using this method can deal with changes that occur in the characteristics of the structure because it can modify its parameters during the control process. A magnetorheological (MR) damper is used as the semi‐active device in this study, whereas a hydraulic actuator is utilized as the active device to control the behavior of the structure. The performance of a three‐story building from the SAC project for the third generation of the control benchmark problem is studied by performing time–history analyses. The structure is subjected to different earthquakes and controlled by the direct adaptive control method. In the analysis of the structure, some stiffness reduction is assumed as a result of potential damage in the first story of the building. Also, the direct adaptive control strategy is used to optimize the response of the undamaged structure and to mitigate the damage impact on the performance of the controlled structure in the presence of noise for output measurements. The results of adaptive control method are compared with those of other control strategies. It is shown that the performance of the three‐story building is improved using the adaptive control method. By assessing the results of different control approaches, it is found that the adaptive control method works more effectively than other methods and semi‐active devices can provide reliable results.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1467-8667.2011.00719.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Bitaraf, M., Hurlebaus, S., & Barroso, L. R.
Venue
Computer-Aided Civil and Infrastructure Engineering
Publisher
Elsevier BV
Published
2011-03-29
Volume
27
Issue
1
Pages
48-64
ISSN
  • 1093-9687 (ISSN-L)
  • 1467-8667
OpenAlex
W1919316260
Cited by
95
References
0
FWCI
26.81
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Active and Semi‐active Adaptive Control for Undamaged and Damaged Building Structures Under Seismic Load. https://app.cochat.ai/papers/10.1111/j.1467-8667.2011.00719.x
The paper
Bitaraf, M., Hurlebaus, S., & Barroso, L. R. (2012). Active and Semi‐active Adaptive Control for Undamaged and Damaged Building Structures Under Seismic Load. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.2011.00719.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.