The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Operational Modal Parameter Identification from Power Spectrum Density Transmissibility
Open accessAbstract
Abstract: Operational modal analysis subjected to ambient or natural excitation under operational conditions has recently drawn great attention. In this article, the power spectrum density transmissibility (PSDT) is proposed to extract the operational modal parameters of a structure. It is proven that the PSDT is independent of the applied excitations and transferring outputs at the system poles. As a result, the modal frequencies and mode shapes can be extracted by combing the PSDTs with different transferring outputs instead of different load conditions where the outputs from only one load condition are needed. A five‐story shear building subjected to a set of uncorrelated forces at different floors is adopted to verify the property of PSDTs and illustrate the accuracy of the proposed method. Furthermore, a concrete‐filled steel tubular half‐through arch bridge tested in the field under operational conditions is used as a real case study. The identification results obtained from currently developed method have been compared with those extracted from peak‐picking method, stochastic subspace identification, and finite element analysis. It is demonstrated that the operational modal parameters identified by the current technique agree well with other independent methods. The real application to the field operational vibration measurements of a full‐sized bridge has shown that the proposed PSDTs are capable of identifying the operational modal parameters (natural frequencies and mode shapes) of a structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Los Alamos National Lab., N. (. S., Doebling, S., USDOE, W., Farrar, C., Prime, M., & Shevitz, D. (1996) · doi:10.2172/249299 · Cited by 2,899 · cited 1×
“The surveys by Doebling et al. (1996) and Sohn et al. (2002) have shown that the structural damage identification through changes in dynamic characteristics such as natural frequencies, mode shapes and their extensions (mode shape curvature, modal flexibility, modal strain energy, etc.) was a…”
Background
Cited by
Signal Processing Techniques for Vibration-Based Health Monitoring of Smart Structures
Amezquita-Sanchez, J. P., & Adeli, H. (2016) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9135-7 · Cited by 487
A novel machine learning‐based algorithm to detect damage in high‐rise building structures
Rafiei, M. H., & Adeli, H. (2017) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1400 · Cited by 346
3D displacement measurement model for health monitoring of structures using a motion capture system
Park, S. W., Park, H. S., Kim, J. H., & Adeli, H. (2015) · Measurement · doi:10.1016/j.measurement.2014.09.063 · Cited by 300
Zhou, Y.-L., Maia, N. M., & Abdel Wahab, M. (2018) · Journal of Vibration and Control · doi:10.1177/1077546316674544 · Cited by 92
Metadata
- Authors
- Yan, W., & Ren, W.
- Venue
- Computer-Aided Civil and Infrastructure Engineering
- Publisher
- Elsevier BV
- Published
- 2011-10-24
- Volume
- 27
- Issue
- 3
- Pages
- 202-217
- ISSN
- 1093-9687 (ISSN-L)
- 1467-8667
- OpenAlex
- W1623680787
- Cited by
- 167
- References
- 1
- FWCI
- 20.34
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operational Modal Parameter Identification from Power Spectrum Density Transmissibility. https://app.cochat.ai/papers/10.1111/j.1467-8667.2011.00735.x
- The paper
- Yan, W., & Ren, W. (2012). Operational Modal Parameter Identification from Power Spectrum Density Transmissibility. Computer-Aided Civil and Infrastructure Engineering. https://doi.org/10.1111/j.1467-8667.2011.00735.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.