Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performance
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Synopsis: The importance of transepidermal water loss (TEWL) as a measure of the skin barrier is well recognized. Currently, the open‐chamber method is dominant, but it is increasingly challenged by newer closed‐chamber technologies. Whilst there is familiarity with open‐chamber characteristics, there is uncertainty about the capabilities of the challengers. The main issues are related to how microclimate affects TEWL measurements. The aim of this paper is to provide a framework for understanding the effects of microclimate on TEWL measurement. Part of the problem is that TEWL measurement is indirect. TEWL is the diffusion of condensed water through the stratum corneum (SC), whereas TEWL methods measure water vapour flux in the air above the SC. This vapour flux depends on (i) the rate of supply of water to the skin surface and (ii) the rate of evaporation of water from the skin surface. Rate (i) is a skin property (TEWL), rate (ii) is a microclimate property. The controlling rate for the combined process is the lower of the above two rates. Therefore, TEWL instruments measure TEWL only when TEWL is the rate‐limiting process. Another problem is that SC barrier property and SC hydration are affected by the microclimate adjacent to the skin surface. This is discussed insofar as it affects the measurement of TEWL. The conclusion is that such changes occur on a timescale that is long compared with TEWL measurement times. An important aspect of TEWL measurement is calibration. We present an analysis of the traditional wet‐cup method and a new droplet method that is traceable and has been independently verified by a standards laboratory. Finally, we review performance indicators of commercial closed‐chamber instruments with reference to open‐chamber instruments. The main findings are that TEWL readings correlate well, but there are significant differences in the other aspects of performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pinnagoda, J., Tupkek, R. A., Agner, T., & Serup, J. (1990) · Contact Dermatitis · doi:10.1111/j.1600-0536.1990.tb01553.x · Cited by 1,092 · cited 10×
“[6] that this boundary layer develops in the absence of natural or forced convection is wrong.”
BackgroundMethodInfluential
Cited by
Alternatives to Biological Skin in Permeation Studies: Current Trends and Possibilities
Neupane, R., Boddu, S. H. S., Renukuntla, J., Babu, R. J., & Tiwari, A. K. (2020) · Pharmaceutics · doi:10.3390/pharmaceutics12020152 · Cited by 351
“Therefore, TEWL requires time for stabilization in a controlled temperature and humidity environment around the probe [42].”
BackgroundResearch Techniques Made Simple: Transepidermal Water Loss Measurement as a Research Tool
Alexander, H., Brown, S., Danby, S., & Flohr, C. (2018) · Journal of Investigative Dermatology · doi:10.1016/j.jid.2018.09.001 · Cited by 288
Transepidermal water loss (TEWL): Environment and pollution—A systematic review
Green, M., Kashetsky, N., Feschuk, A., & Maibach, H. I. (2022) · Skin Health and Disease · doi:10.1002/ski2.104 · Cited by 86
“Imhof et al.6 describe how the microclimate between the skin surface and measurement device contribute greatly to measurement accuracy, with rate of evaporation due to skin surface temperature contributing to potential error in measurement without proper calibration.”
Background(2011) · PubMed · Cited by 76
Nanostructuring Lipid Carriers Using Ridolfia segetum (L.) Moris Essential Oil
Miranda, M., Cruz, M. T., Vitorino, C., & Cabral, C. (2019) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.109804 · Cited by 45
Metadata
- Authors
- Imhof, R. E., De Jesus, M. E. P., Xiao, P., Ciortea, L. I., & Berg, E. P.
- Venue
- International Journal of Cosmetic Science
- Publisher
- Wiley
- Published
- 2009-02-24
- Volume
- 31
- Issue
- 2
- Pages
- 97-118
- ISSN
- 0142-5463 (ISSN-L)
- 1468-2494
- OpenAlex
- W2021820072
- Cited by
- 140
- References
- 1
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performance. https://app.cochat.ai/papers/10.1111/j.1468-2494.2008.00476.x
- The paper
- Imhof, R. E., De Jesus, M. E. P., Xiao, P., Ciortea, L. I., & Berg, E. P. (2009). Closed‐chamber transepidermal water loss measurement: microclimate, calibration and performance. International Journal of Cosmetic Science. https://doi.org/10.1111/j.1468-2494.2008.00476.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.