Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Age‐related changes in mechanical properties of the Achilles tendon

Open access
Waugh, C. M., Blazevich, A. J., Fath, F., Korff, T. · 2012 · Journal of Anatomy

Abstract

The stiffness of a tendon, which influences muscular force transfer to the skeleton and increases during childhood, is dependent on its material properties and dimensions, both of which are influenced by chronic loading. The aims of this study were to: (i) determine the independent contributions of body mass, force production capabilities and tendon dimensions to tendon stiffness during childhood; and (ii) descriptively document age‐related changes in tendon mechanical properties and dimensions. Achilles tendon mechanical and material properties were determined in 52 children (5–12 years) and 19 adults. Tendon stiffness and Young’s modulus (YM) were calculated as the slopes of the force–elongation and stress‐strain curves, respectively. Relationships between stiffness vs. age, mass and force, and between YM vs. age, mass and stress were determined by means of polynomial fits and multiple regression analyses. Mass was found to be the best predictor of stiffness, whilst stress was best related to YM (< 75 and 51% explained variance, respectively). Combined, mass and force accounted for up to 78% of stiffness variation. Up to 61% of YM variability could be explained using a combination of mass, stress and age. These results demonstrate that age‐related increases in tendon stiffness are largely attributable to increased tendon loading from weight‐bearing tasks and increased plantarflexor force production, as well as tendon growth. Moreover, our results suggest that chronic increases in tendon loading during childhood result in microstructural changes which increase the tendon’s YM. Regarding the second aim, peak stress increased from childhood to adulthood due to greater increases in strength than tendon cross‐sectional area. Peak strain remained constant as a result of parallel increases in tendon length and peak elongation. The differences in Achilles tendon properties found between adults and children are likely to influence force production, and ultimately movement characteristics, which should be explicitly examined in future research.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7580.2011.01461.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 176

Metadata

Authors
Waugh, C. M., Blazevich, A. J., Fath, F., & Korff, T.
Venue
Journal of Anatomy
Publisher
Wiley
Published
2011-12-07
Volume
220
Issue
2
Pages
144-155
ISSN
  • 0021-8782 (ISSN-L)
  • 1469-7580
OpenAlex
W1595764159
Cited by
176
References
2
FWCI
7.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Age‐related changes in mechanical properties of the Achilles tendon. https://app.cochat.ai/papers/10.1111/j.1469-7580.2011.01461.x
The paper
Waugh, C. M., Blazevich, A. J., Fath, F., & Korff, T. (2012). Age‐related changes in mechanical properties of the Achilles tendon. Journal of Anatomy. https://doi.org/10.1111/j.1469-7580.2011.01461.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.