CoChat

Elimination of the transient outward current and action potential prolongation in mouse atrial myocytes expressing a dominant negative Kv4 α subunit

Open access
Xu, Haodong, Li, Huilin, Nerbonne, Jeanne M. · 1999 · The Journal of Physiology
Cited by 95

The DOI matches its Crossref record.

Abstract

1. Analyses of whole-cell voltage-clamp recordings from isolated adult (C57BL6) mouse atrial myocytes reveal the presence of two prominent Ca2+-independent depolarization-activated K+ currents: a rapidly activating and inactivating, transient outward K+ current, Ito,f; and a non-inactivating, steady-state, K+ current, Iss. 2. The properties of Ito,f and Iss in adult mouse atrial myocytes are similar to those of the analogous currents recently described in detail in adult mouse ventricular cells. A slowly inactivating K+ current, which is similar to IK,slow in ventricular cells, is detected in approximately 40 % of adult mouse atrial myocytes, and when expressed, the density of this current component is substantially lower than the density of Ito,f or Iss. 3. The similarity between atrial and ventricular Ito,f and the finding that both the Kv4 subfamily alpha subunits, Kv4.2 and Kv4.3, are expressed in wild-type mouse atria prompted us to determine if atrial Ito,f is affected in transgenic mice expressing a mutant Kv4. 2 alpha subunit, Kv4.2W362F, that functions as a dominant negative. 4. Similar to findings in ventricular cells, electrophysiological recordings reveal that Ito,f is selectively eliminated in atrial myocytes isolated from transgenic mice expressing Kv4.2W362F, thereby demonstrating directly that Kv4 subfamily members also underlie mouse atrial Ito,f. 5. Neither the steady-state, non-inactivating K+ current Iss, nor the inwardly rectifying K+ current IK1, in atrial myocytes is affected by the expression of Kv4. 2W362F.6 In contrast to previous findings in Kv4.2W362F-expressing mouse ventricular myocytes, there is no evidence that electrical remodelling occurs in atrial cells when Ito,f is functionally eliminated. 6. The elimination of Ito,f is accompanied by marked increases in atrial action potential durations, although no electrocardiographic abnormalities attributable to, or suggestive of, altered atrial functioning are evident in Kv4.2W362F-expressing animals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1999.0011o.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 95

Metadata

Authors
Xu, H., Li, H., & Nerbonne, J. M.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1999-08
Volume
519
Issue
1
Pages
11-21
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2000769130
Cited by
95
References
0
FWCI
6.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Elimination of the transient outward current and action potential prolongation in mouse atrial myocytes expressing a dominant negative Kv4 α subunit. https://app.cochat.ai/papers/10.1111/j.1469-7793.1999.0011o.x
The paper
Xu, H., Li, H., & Nerbonne, J. M. (1999). Elimination of the transient outward current and action potential prolongation in mouse atrial myocytes expressing a dominant negative Kv4 α subunit. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1999.0011o.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.