Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 327

The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.

Task‐dependent modulation of 15‐30 Hz coherence between rectified EMGs from human hand and forearm muscles

Open access
Kilner, J. M., Baker, S. N., Salenius, S., Jousmäki, V., Hari, R., Lemon, R. N.·1999·The Journal of Physiology

Abstract

1. Recent reports have shown task-related changes in oscillatory activity in the 15-30 Hz range in the sensorimotor cortex of human subjects and monkeys during skilled hand movements. In the monkey these oscillations have been shown to be coherent with oscillatory activity in the electromyographic activity of hand and forearm muscles. 2. In this study we investigated the modulation of oscillations in the electromyogram (EMG) of human volunteers during tasks requiring precision grip of two spring-loaded levers. 3. Two tasks were investigated: in the 'hold' task, subjects were required to maintain a steady grip force (ca 2.1 N or 2.6 N) for 8 s. In the 'ramp' task, there was an initial hold period for 3 s (force ca 2.1 N) followed by a linear increase in grip force over a 2 s period. The task ended with a further steady hold for 3 s at the higher force level (ca 2.6 N). 4. Surface EMGs were recorded from five hand and forearm muscles in 12 subjects. The coherence of oscillatory activity was calculated between each muscle pair. Frequencies between 1 and 100 Hz were analysed. 5. Each subject showed a peak in the coherence spectra in the 15-30 Hz bandwidth during the hold task. This coherence was absent during the initial movement of the levers. During the ramp task the coherence in the 15-30 Hz range was also significantly reduced during the movement phase, and significantly increased during the second hold period, relative to the initial hold. 6. There was coherence between the simultaneously recorded magnetoencephalogram (MEG) and EMG during steady grip in the hold task; this coherence disappeared during the initial lever movement. Using a single equivalent current dipole source model, the coherent cortical activity was localized to the hand region of the contralateral motor cortex. This suggests that the EMG-EMG coherence was, therefore, at least in part, of cortical origin. 7. The results are discussed in terms of a possible role for synchrony in the efficient recruitment of motor units during maintained grip.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1999.0559v.x

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Cited by

See all 327

Metadata

Authors
Kilner, J. M., Baker, S. N., Salenius, S., Jousmäki, V., Hari, R., & Lemon, R. N.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1999-04
Volume
516
Issue
2
Pages
559-570
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2128181457
Cited by
327
References
44
FWCI
15.76
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Task‐dependent modulation of 15‐30 Hz coherence between rectified EMGs from human hand and forearm muscles. https://app.cochat.ai/papers/10.1111/j.1469-7793.1999.0559v.x
The paper
Kilner, J. M., Baker, S. N., Salenius, S., Jousmäki, V., Hari, R., & Lemon, R. N. (1999). Task‐dependent modulation of 15‐30 Hz coherence between rectified EMGs from human hand and forearm muscles. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1999.0559v.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.