The DOI matches its Crossref record.
Heart rate variability is encoded in the spontaneous discharge of thalamic somatosensory neurones in cat
Open accessAbstract
1. We studied the spontaneous discharge variability of thalamocortical somatosensory neurones in the awake cat in order to disclose its possible information content. The presence of slow (0.09-1.39 Hz) regular fluctuations in the discharge rate of these cells during the waking state has been previously reported. Oscillations in a similar frequency range are known to characterize the activity of central and peripheral neurones pertaining to the autonomic nervous system and the variability of heart period (RR interval variability). 2. A surrogate data test, performed on our database, confirmed the presence of slow (0.05-1 Hz) non-random fluctuations in firing rate. 3. Linear regression detected the presence of an inverse relationship between the values of RR interval and the concurrent levels of neural discharge. 4. Frequency domain analysis indicated that a significant coupling between the two variability signals preferentially occurred in two frequency bands: in the frequency of the respiratory sinus arrhythmia and in correspondence with a slower rhythm (0.07-0.3 Hz), the two signals being in phase opposition in most of the cases. 5. Coherent fluctuations could also be observed when epochs of evoked activity were analysed, while coupling between the two variability signals appeared to be disrupted after sleep onset. 6. We conclude that RR interval variability, an internally generated dynamic related to basic visceral regulation, is encoded in the discharge of single somatosensory thalamocortical neurones during wakefulness. A possible interaction with the transmission of somatosensory information has to be evaluated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
This is the first report relating to heart rate variability in ambulatory pet cats.
“to the author's knowledge, this is the first report that relates to heart rate variability in ambulatory pet cats.”
From Heart rate and heart rate variability of healthy cats in home and hospital environments (2005) · cites this paper as Massimini et al 2000
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 32
- 10.1109/TAC.1974.1100705 · DOI · Paper page
- 10.1016/S0306-4522(97)00633-7 · DOI
- 10.1109/10.641336 · DOI
- 10.1113/jphysiol.1991.sp018597 · DOI
- 10.1016/0034-5687(92)90137-L · DOI
- 10.1007/BF02441589 · DOI
- 10.1016/0013-4694(89)90222-8 · DOI
- 10.1016/0006-8993(83)91264-7 · DOI · Paper page
- 10.1113/jphysiol.1984.sp015153 · DOI
- 10.1109/PROC.1981.12184 · DOI
- 10.1016/S0165-1838(97)00126-4 · DOI
- Langhorst P., 1986, Neural Mechanisms and Cardiovascular Diseases, 133
- 10.1016/0165-1838(95)00132-8 · DOI
- 10.1146/annurev.neuro.20.1.185 · DOI · Paper page
- Malliani A., 1999, The pattern of sympathovagal balance explored in the frequency domain, News in Physiological Sciences, 14, 111
- 10.1161/01.CIR.84.2.482 · DOI · Paper page
- Mariotti M., 1990, The Dyencephalon and Sleep, 301
- 10.1016/0165-1838(95)00113-1 · DOI
- 10.1016/0165-1838(92)90222-3 · DOI · Paper page
- 10.1007/BF00337149 · DOI
- 10.1016/0006-8993(82)91252-5 · DOI
- 10.2170/jjphysiol.16.612 · DOI
- 10.1161/01.CIR.95.6.1441 · DOI
- 10.1152/ajplegacy.1974.226.3.724 · DOI
- 10.1016/0165-1838(83)90006-1 · DOI
- 10.1016/0165-1838(85)90039-6 · DOI
- Shimamura M., 1982, Sensory evoked potentials and their changes with respiration in mnd cat, Electroencephalography and Clinical Neurophysiology, 297
- 10.1523/JNEUROSCI.13-08-03284.1993 · DOI
- 10.1016/0165-0173(84)90017-1 · DOI
- Theiler A., 1992, Testing for nonlinearity in time series: the method of surrogate data, Physica, 58, 239
- 10.1152/jn.1963.26.6.958 · DOI
- 10.1016/0014-4886(86)90037-3 · DOI
Cited by
Sorted by citations
Heart rate and heart rate variability of healthy cats in home and hospital environments
Abbott, J. A. (2005) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2004.12.003 · Cited by 92
Kim, K., Ladenbauer, J., Babo-Rebelo, M., Buot, A., Lehongre, K., Adam, C., Hasboun, D., Lambrecq, V., Navarro, V., Ostojic, S., et al. (2019) · The Journal of Neuroscience · doi:10.1523/jneurosci.2291-18.2019 · Cited by 39
Metadata
- Authors
- Massimini, M., Porta, A., Mariotti, M., Malliani, A., & Montano, N.
- Affiliations
- University of Milan (IT)
- Corresponding author
- Massimini, Marcello
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2000-07
- Volume
- 526
- Issue
- 2
- Pages
- 387-396
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- PMC
- PMC2270016
- OpenAlex
- W2089285896
- Cited by
- 34
- References
- 0
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 1 · 2022: 1 · 2021: 2 · 2019: 2 · 2018: 2 · 2014: 1 · 2013: 2 · 2012: 1
- FWCI
- 0.74
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- The Journal of Physiology (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Life Sciences › Neuroscience › Endocrine and Autonomic Systems › Neuroscience of respiration and sleep
- Keywords
- heart rate variability, thalamocortical neurons, spontaneous neuronal discharge, respiratory sinus arrhythmia, RR interval variability, neural oscillations, surrogate data analysis, coherence analysis, sleep onset, autonomic regulation, cats
- MeSH terms
- Activity Cycles, Animals, Cats, Electrocardiography, Electroencephalography, Hair, Heart Rate, Neurons, Oscillometry, Regression Analysis, Skin, Somatosensory Cortex, Thalamus
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review