The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Why are mammalian tendons so thick?
Abstract
The maximum stresses to which a wide range of mammalian limb tendons could be subjected in life were estimated by considering the relative cross‐sectional areas of each tendon and of the fibres of its muscle. These cross‐sectional areas were derived from mass and length measurements on tendons and muscles assuming published values for the respective densities. The majority of the stresses are low. The distribution has a broad peak with maximum frequency at a stress of about 13 MPa, whereas the fracture stress for tendon in tension is about 100 MPa. Thus, the majority of tendons are far thicker than is necessary for adequate strength. Much higher stresses are found among those tendons which act as springs to store energy during locomotion. The acceptability of low safety factors in these tendons has been explained previously (Alexander, 1981). A new theory explains the thickness of the majority of tendons. The muscle with its tendon is considered as a combined system which delivers mechanical energy: the thickness of the tendon is optimized by minimizing the combined mass. A thinner tendon would stretch more. To take up this stretch, the muscle would require longer muscle fibres, which would increase the combined mass. The predicted maximum stress in a tendon of optimum thickness is about 10 MPa, which is within the main peak of the observed stress distribution. Individual variations from this value are to be expected and can be understood in terms of the functions of the various muscles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Density and composition of mammalian muscle
Méndez, J., & Keys, A. (1960) · Metabolism · Cited by 802
The spring in the arch of the human foot
Ker, R. F., Bennett, M. B., Bibby, S. R., Kester, R. C., & Alexander, R. M. (1987) · Nature · doi:10.1038/325147a0 · Cited by 764
Self-citationThe mechanics of hopping by kangaroos (Macropodidae)
Alexander, R. M., & Vernon, A. (1975) · Journal of Zoology · doi:10.1111/j.1469-7998.1975.tb05983.x · Cited by 536
Self-citationThe energetics of the jump of the locust Schistocerca gregaria
Bennet-Clark, H. C. (1975) · Journal of Experimental Biology · doi:10.1242/jeb.63.1.53 · Cited by 450
Elastic Energy Stores in Running Vertebrates
ALEXANDER, R. M. (1984) · American Zoologist · doi:10.1093/icb/24.1.85 · Cited by 411
Self-citationMechanical properties of various mammalian tendons
Bennett, M. B., Ker, R. F., Imery, N. J., & Alexander, R. M. (1986) · Journal of Zoology · doi:10.1111/j.1469-7998.1986.tb03609.x · Cited by 368
Self-citationDynamic Tensile Properties of the Plantaris Tendon of Sheep (Ovis Aries)
Ker, R. F. (1981) · Journal of Experimental Biology · doi:10.1242/jeb.93.1.283 · Cited by 345
Self-citationCross‐bridge detachment and sarcomere 'give' during stretch of active frog's muscle.
Flitney, F. W., & Hirst, D. G. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012246 · Cited by 282
Elastic structures in the back and their rôle in galloping in some mammals
Alexander, R. M., Dimery, N. J., & Ker, R. F. (1985) · Journal of Zoology · doi:10.1111/j.1469-7998.1985.tb04944.x · Cited by 258
Self-citationFactors of safety in the structure of animals.
Rm, A. (1981) · PubMed · Cited by 246
Cited by
Bojsen-Møller, J., Magnusson, S. P., Rasmussen, L. R., Kjaer, M., & Aagaard, P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01305.2004 · Cited by 532
In vivo human tendon mechanical properties
Maganaris, C. N., & Paul, J. P. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00307.x · Cited by 494
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035576 · Cited by 484
Region specific patellar tendon hypertrophy in humans following resistance training
Kongsgaard, M., Reitelseder, S., Pedersen, T. G., Holm, L., Aagaard, P., Kjaer, M., & Magnusson, S. P. (2007) · Acta Physiologica · doi:10.1111/j.1748-1716.2007.01714.x · Cited by 377
Tendon elasticity and muscle function
McNeill Alexander, R. (2002) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(02)00143-5 · Cited by 355
Metadata
- Authors
- KER, R. F., ALEXANDER, R. M., & BENNETT, M. B.
- Venue
- Journal of Zoology
- Publisher
- Wiley
- Published
- 1988-10
- Volume
- 216
- Issue
- 2
- Pages
- 309-324
- ISSN
- 0952-8369 (ISSN-L)
- 1469-7998
- OpenAlex
- W2013244204
- Cited by
- 377
- References
- 22
- FWCI
- 4.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Why are mammalian tendons so thick? https://app.cochat.ai/papers/10.1111/j.1469-7998.1988.tb02432.x
- The paper
- KER, R. F., ALEXANDER, R. M., & BENNETT, M. B. (1988). Why are mammalian tendons so thick? Journal of Zoology. https://doi.org/10.1111/j.1469-7998.1988.tb02432.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.