Evaluation of a New Ambulatory Blood Pressure Monitor (Accutracker 102): Laboratory Comparisons With Direct Arterial Pressure, Stethoscopic Auscultatory Pressure, and Readings From a Similar Monitor (Spacelabs Model 5200)
The DOI matches its Crossref record.
Abstract
Systolic (SBP) and diastolic (DBP) blood pressure levels generated by a new noninvasive ambulatory monitor, the Accutracker 102, were compared in the laboratory with intra‐arterial pressure levels in 12 normotensive men, and with stethoscopic auscultatory determinations in 27 normotensive and hypertensive men and women over a wide range of within‐subject pressure variations. In 11 subjects, its performance was also compared with another ambulatory monitor, the Spacelabs Model 5200. Highly positive correlations with both the intra‐arterial (median r=+.90 for SBP, +.92 for DBP) and the stethoscopic standards (median r=+.93 for SBP, +.88 for DBP) were obtained using Accutracker's automatic readings (digital readout), while slightly higher correlations were obtained with hand‐scoring of recorded data. The Spacelabs BP monitor also yielded readings that were highly correlated with stethoscopic readings (median r=+.83 for SBP, +.77 for DBP), although in 3 of the 11 subjects the Accutracker correlations were substantially higher than the Spacelabs correlations. Despite their generally good tracking of changes in pressure, both ambulatory monitors yielded absolute values in many subjects that differed by 5 mmHg or more from stethoscopic levels. The Accutracker's SBP levels were consistently too high and its DBP levels were occasionally too low, while Spacelabs' SBP and DBP values were too high and too low with equal frequency. However, mean deviation scores for each patient calculated from 5 concurrent ambulatory monitor and stethoscopic readings were shown to yield relatively stable correction factors for use when comparison with clinical standards is desired.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grewen, K. M., Girdler, S. S., Amico, J., & Light, K. C. (2005) · Psychosomatic Medicine · doi:10.1097/01.psy.0000170341.88395.47 · Cited by 513
Self-citationHolt-Lunstad, J., Birmingham, W. A., & Light, K. C. (2008) · Psychosomatic Medicine · doi:10.1097/psy.0b013e318187aef7 · Cited by 473
Self-citationLight, K. C., Grewen, K. M., & Amico, J. A. (2005) · Biological Psychology · doi:10.1016/j.biopsycho.2004.11.002 · Cited by 470
Self-citationBlumenthal, J. A. (1991) · JAMA · doi:10.1001/jama.1991.03470150070033 · Cited by 181
Light, K. C., Smith, T. E., Johns, J. M., Brownley, K. A., Hofheimer, J. A., & Amico, J. A. (2000) · Health Psychology · doi:10.1037/0278-6133.19.6.560 · Cited by 154
Self-citation
Metadata
- Authors
- Light, K. C., Obrist, P. A., & Cubeddu, L. X.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1988-01
- Volume
- 25
- Issue
- 1
- Pages
- 107-116
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2048386597
- Cited by
- 53
- References
- 0
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a New Ambulatory Blood Pressure Monitor (Accutracker 102): Laboratory Comparisons With Direct Arterial Pressure, Stethoscopic Auscultatory Pressure, and Readings From a Similar Monitor (Spacelabs Model 5200). https://app.cochat.ai/papers/10.1111/j.1469-8986.1988.tb00969.x
- The paper
- Light, K. C., Obrist, P. A., & Cubeddu, L. X. (1988). Evaluation of a New Ambulatory Blood Pressure Monitor (Accutracker 102): Laboratory Comparisons With Direct Arterial Pressure, Stethoscopic Auscultatory Pressure, and Readings From a Similar Monitor (Spacelabs Model 5200). Psychophysiology. https://doi.org/10.1111/j.1469-8986.1988.tb00969.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.