CoChat

Auditory and Visual P300s in Temporal Lobectomy Patients: Evidence for Modality‐Dependent Generators

Johnson, Ray · 1989 · Psychophysiology
Cited by 157

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The P300 component of the event‐related brain potential (ERP) was studied in epileptic patients with unilateral resections of medial temporal lobe areas of the brain. The patients and controls were tested in an oddball paradigm in two conditions: counting and reaction time. Both auditory and visual stimuli were used to elicit ERP activity in different blocks. Despite the reported presence of locally‐generated auditory and visual P300‐like potentials in these areas, no evidence was found of any surgically‐related hemispheric asymmetries in the scalp distribution of the P300 or Slow Wave for stimuli in either modality. Moreover, compared to normal controls, there were no significant reductions in overall P300 amplitude in the patients. The patients did show a double dissociation in their frontal ERP activity: the left temporal lobectomy patients showed apparent decreased frontal auditory P300 amplitudes but normal visual P300 amplitudes, whereas the right temporal lobectomy patients showed the opposite pattern. These results appeared to be due to the presence of a longduration slow wave rather than to alterations in P300 amplitude. These data do not support the presence of a significant contribution by a hippocampal/amygdala generator to the activity of the scalp‐recorded P300 in the oddball paradigm. Topographic comparisons on normalized amplitudes revealed significantly different scalp distributions as a function of stimulus modality, event probability, and task for both the P300 and Slow Wave components. These data indicate that the amplitude variations associated with each experimental variable are due to the activity of a separate underlying neural source. The sources of task and probability effects on P300 and Slow Wave amplitude each appeared to be modality‐independent generators. The nature of the third, modality‐related generator is less clear. These results uphold the tenets of the model of P300 amplitude proposed by Johnson (1986) and argue against the idea that the P300 is a unitary phenomenon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-8986.1989.tb03165.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 157

Metadata

Authors
Johnson, R.
Venue
Psychophysiology
Publisher
Wiley
Published
1989-11
Volume
26
Issue
6
Pages
633-650
ISSN
  • 0048-5772 (ISSN-L)
  • 1469-8986
OpenAlex
W1998456338
Cited by
157
References
3
FWCI
4.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Auditory and Visual P300s in Temporal Lobectomy Patients: Evidence for Modality‐Dependent Generators. https://app.cochat.ai/papers/10.1111/j.1469-8986.1989.tb03165.x
The paper
Johnson, R. (1989). Auditory and Visual P300s in Temporal Lobectomy Patients: Evidence for Modality‐Dependent Generators. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1989.tb03165.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.