Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 205

The DOI matches its Crossref record.

Individual Differences in Behaviorally Evoked Cardiovascular Response: Temporal Stability and Hemodynamic Patterning

Kasprowicz, Alfred L., Manuck, Stephen B., Malkoff, Susan B., Krantz, David S. · 1990 · Psychophysiology

Abstract

This study evaluates the reproducibility of individual differences in behaviorally evoked cardiovascular reactivity among 39 young adult males. Presented also are initial data describing idiosyncratic patterns of hemodynamic adjustment that may underlie pressor responses to laboratory stressors. Subjects were administered three experimental stressors (mental arithmetic, mirror tracing, and bicycle exercise) on two occasions, four weeks apart. Heart rate, blood pressure, and impedance‐derived measurements of cardiac pre‐ejection period, stroke index, cardiac index, and total peripheral resistance were obtained during baseline and task periods at each session. To index task‐induced “reactivity,” residualized (baseline‐adjusted) change scores were calculated for all variables; percentage change from baseline was also calculated for impedance‐derived hemodynamic measurements. Test‐retest (inter‐session) correlations were significant for nearly all baseline, task, and change‐score measurements. The few exceptions included diastolic blood pressure changes during mirror tracing and bicycle exercise and changes in stroke index and peripheral resistance during mental arithmetic. Although virtually all baseline and task correlations exceeded .60, reactivity indices yielded consistently lower retest correlations (significant r's = .35‐.78; median r= .49). In subsequent analyses, subsets of individuals were identified whose reactions to mental arithmetic at the first laboratory session reflected changes in either cardiac output (CI reactors, n = 9) or total peripheral resistance (TPR reactors, n = 6), or a combination of cardiac and vascular influences (Mixed reactors, n = 8). This typology of hemodynamic response: (a) was corroborated by corresponding group differences in heart rate, pre‐ejection period, and stroke index; (b) was reproducible on retesting; and (c) showed some generalization to the mirror tracing task, though not to bicycle exercise.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-8986.1990.tb03181.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 205

Metadata

Authors
Kasprowicz, A. L., Manuck, S. B., Malkoff, S. B., & Krantz, D. S.
Venue
Psychophysiology
Publisher
Wiley
Published
1990-11
Volume
27
Issue
6
Pages
605-619
ISSN
  • 0048-5772 (ISSN-L)
  • 1469-8986
OpenAlex
W2028010177
Cited by
205
References
0
FWCI
8.07
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Individual Differences in Behaviorally Evoked Cardiovascular Response: Temporal Stability and Hemodynamic Patterning. https://app.cochat.ai/papers/10.1111/j.1469-8986.1990.tb03181.x
The paper
Kasprowicz, A. L., Manuck, S. B., Malkoff, S. B., & Krantz, D. S. (1990). Individual Differences in Behaviorally Evoked Cardiovascular Response: Temporal Stability and Hemodynamic Patterning. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1990.tb03181.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.