Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Eye movement artifacts in electroencephalogram (EEG) recordings can greatly distort grand mean event-related potential (ERP) waveforms. Different techniques have been suggested to remove these artifacts prior to ERP analysis. Independent component analysis (ICA) is suggested as an alternative method to "filter" eye movement artifacts out of the EEG, preserving the brain activity of interest and preserving all trials. However, the identification of artifact components is not always straightforward. Here, we compared eye movement artifact removal by ICA compiled on 10 s of EEG, on eye movement epochs, or on the complete EEG recording to the removal of eye movement artifacts by rejecting trials or by the Gratton and Coles method. ICA performed as well as the Gratton and Coles method. By selecting only eye movement epochs for ICA compilation, we were able to facilitate the identification of components representing eye movement artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055 · cited 2×
“…of the eye artifact removal by ICA to (a) data uncorrected for eye movements, (b) data corrected for eye movements by rejecting EEG epochs with an amplitude exceeding 100 mV, and (c) to the results of eye artifact removal by the well-established Gratton and Coles method (Gratton et al., 1983).”
BackgroundMethodA three-dimensional statistical analysis for CBF activation studies in human brain
Worsley, K. J., Evans, A. C., Marrett, S., & Neelin, P. (1992) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1992.127 · Cited by 2,036
Mental Training Affects Distribution of Limited Brain Resources
Slagter, H. A., Lutz, A., Greischar, L. L., Francis, A. D., Nieuwenhuis, S., Davis, J. M., & Davidson, R. J. (2007) · PLoS Biology · doi:10.1371/journal.pbio.0050138 · Cited by 757 · cited 2×
“data (Debener, Hine, Bleeck, & Eyles, 2008; Huang, Jung, Delorme, &Makeig, 2008; Jung et al., 2001; Joyce, Gorodnitsky, & Kutas, 2004; Slagter et al., 2007).”
Neural Systems for Visual Orienting and Their Relationships to Spatial Working Memory
Corbetta, M., Kincade, J. M., & Shulman, G. L. (2002) · Journal of Cognitive Neuroscience · doi:10.1162/089892902317362029 · Cited by 698
A multiple source approach to the correction of eye artifacts
Berg, P., & Scherg, M. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90094-9 · Cited by 696 · cited 1×
“Consequently, several methods that try to remove as much of the eye movement artifacts without reducing data quality have been introduced (Berg & Scherg, 1994; Croft & Barry, 2000; Gratton, Coles, & Donchin, 1983).”
Method
Cited by
Regional brain wave activity changes associated with fatigue
Craig, A., Tran, Y., Wijesuriya, N., & Nguyen, H. (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2011.01329.x · Cited by 359
Methods for Simultaneous EEG-fMRI: An Introductory Review
Huster, R. J., Debener, S., Eichele, T., & Herrmann, C. S. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.0447-12.2012 · Cited by 308
A novel hybrid BCI speller based on the incorporation of SSVEP into the P300 paradigm
Yin, E., Zhou, Z., Jiang, J., Chen, F., Liu, Y., & Hu, D. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/2/026012 · Cited by 225
Optimizing the ICA-based removal of ocular EEG artifacts from free viewing experiments
Dimigen, O. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116117 · Cited by 222
“Obviously, the success of this procedure depends on an appropriate threshold. Although a value of 1 seems like a logical choice, Plöchl et al. (2012) proposed using a slightly higher threshold (1.”
BackgroundMasia, V., Canal, P., Ricci, I., Vallauri, E. L., & Bambini, V. (2017) · Journal of Neurolinguistics · doi:10.1016/j.jneuroling.2016.11.005 · Cited by 110
Metadata
- Authors
- Mennes, M., Wouters, H., Vanrumste, B., Lagae, L., & Stiers, P.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2010-04
- Volume
- 47
- Issue
- 6
- Pages
- 1142-50
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2033205888
- Cited by
- 116
- References
- 6
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP. https://app.cochat.ai/papers/10.1111/j.1469-8986.2010.01015.x
- The paper
- Mennes, M., Wouters, H., Vanrumste, B., Lagae, L., & Stiers, P. (2010). Validation of ICA as a tool to remove eye movement artifacts from EEG/ERP. Psychophysiology. https://doi.org/10.1111/j.1469-8986.2010.01015.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.