Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record.

Pregnancy outcomes and cardiac complications in women with mechanical, bioprosthetic and homograft valves

Sadler, Lynn, McCowan, Lesley, White, Harvey, Stewart, Alistair, Bracken, Michael, North, Robyn·2000·BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Objectives Firstly, to compare pregnancy outcomes and cardiac complications in women with: 1. either mechanical or bioprosthetic valves at the mitral site; 2. mechanical valves treated with warfarin or subcutaneous heparin. Secondly, to determine pregnancy and cardiac outcomes in women with aortic homograft valves. Design Historical cohort study. Setting Greenlane Hospital, Auckland, New Zealand. Population Young women (n= 255) who had valve replacements between 1972 and 1992. Seventy‐nine women underwent 147 pregnancies. Main outcome measures Pregnancy loss, cardiac complications. Results Pregnancy loss occurred in 59% of pregnancies with mitral mechanical valves (n= 50) and 7% with mitral bioprosthetic valves (n= 33) (RR 8.20,95% CI2.10–31.93). Pregnancy loss rate was 70% in pregnancies treated with warfarin, compared with 25% for those switched from warfarin to heparin (RR 2.81, 95% CI 1.03–7.73). All heparin‐associated losses occurred in the first trimester, whereas there were four stillbirths with warfarin. Cardiac complications occurred in 10 pregnancies (20%) in the women with mitral mechanical valves and four (13%) with mitral bioprosthetic valves (RR 1.55, 95% CI 0.53–4.52). All four thromboembolic complications with mechanical valves occurred in the 14 women treated with heparin throughout pregnancy. Structural valve deterioration occurred in four pregnancies (10%) with mitral bioprosthetic valves. No cardiac complications or known pregnancy losses occurred with aortic homograft valves (n= 41). Conclusion The high pregnancy loss rate in women with mitral mechanical valves was associated with warfarin throughout pregnancy, whereas the thromboembolic cardiac complications were associated with heparin. Pregnancy outcome was very good in women with bioprosthetic and homograft valves.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2000.tb11696.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 207

Metadata

Authors
Sadler, L., McCowan, L., White, H., Stewart, A., Bracken, M., & North, R.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2000-02
Volume
107
Issue
2
Pages
245-253
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2091930890
Cited by
207
References
0
FWCI
5.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pregnancy outcomes and cardiac complications in women with mechanical, bioprosthetic and homograft valves. https://app.cochat.ai/papers/10.1111/j.1471-0528.2000.tb11696.x
The paper
Sadler, L., McCowan, L., White, H., Stewart, A., Bracken, M., & North, R. (2000). Pregnancy outcomes and cardiac complications in women with mechanical, bioprosthetic and homograft valves. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2000.tb11696.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.