Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 228

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Transvaginal repair of anterior and posterior compartment prolapse with Atrium polypropylene mesh

Dwyer, Peter L., O'Reilly, Barry A.·2004·BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Objective To determine the efficacy and safety of a new technique using Atrium polypropylene mesh (Atrium, Hudson, New Hampshire, USA) as an overlay graft for repair of large or recurrent anterior and posterior compartment prolapse. Design A retrospective review of women who had vaginal prolapse surgery with Atrium mesh reinforcement. Setting Tertiary referral urogynaecology unit in Australia. Population Forty‐seven women where mesh was placed under the bladder base with lateral extensions onto the pelvic sidewall, 33 women where a Y‐shaped mesh was placed from the sacrospinous ligaments to the perineal body and 17 women who had mesh placement in both compartments. Methods Women were assessed by site‐specific vaginal examination pre‐operatively and post‐operatively at six weeks, six months and two years. Main outcome measures All complications. Rate of recurrent prolapse assessed by the Baden–Walker halfway classification system. Results Mean follow up was 29 months (range 6 to 52). Four of 64 women with anterior mesh placement (6%) developed a grade 2 asymptomatic cystocele. Five women (5%) required further surgery for recurrent prolapse at a non‐mesh site. Erosion occurred in nine women (9%). Three healed after intravaginal oestrogen cream, five after excision of exposed mesh and vaginal closure and one woman also had surgical closure of a rectovaginal fistula. The risk of mesh erosion decreased over the study period. Urinary, coital and bowel symptoms were significantly improved following surgery. Conclusions This technique shows promise in correcting pelvic organ prolapse. Vaginal mesh erosion is the most common complication and is related to surgical experience.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2004.00194.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 228

Metadata

Authors
Dwyer, P. L., & O'Reilly, B. A.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2004-07-16
Volume
111
Issue
8
Pages
831-836
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2033706944
Cited by
228
References
1
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transvaginal repair of anterior and posterior compartment prolapse with Atrium polypropylene mesh. https://app.cochat.ai/papers/10.1111/j.1471-0528.2004.00194.x
The paper
Dwyer, P. L., & O'Reilly, B. A. (2004). Transvaginal repair of anterior and posterior compartment prolapse with Atrium polypropylene mesh. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2004.00194.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.