Cited by 96Reproductive Health and ContraceptionMaternal and Perinatal Health InterventionsInternational Human Rights and Reproductive Law

Manual versus electric vacuum aspiration for first‐trimester abortion: a systematic review

Wen, J, Cai, QY, Deng, F, Li, YP·2008·BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Background As an alternative to electric vacuum aspirations (EVA), there is an increasing interest in using manual vacuum aspiration (MVA). Objective To compare the safety, efficacy and acceptability of MVA with those of EVA for first-trimester abortion. Search strategy We searched MEDLINE, EMBASE, Cochrane Library and Chinese Biomedical Database in all language, together with reference lists of retrieved papers. Selection criteria Randomised controlled trials comparing MVA with EVA for first-trimester abortion were included. The outcomes are complete abortion rate, uterine perforation rate, blood loss, pain perception and acceptability. Data collection and analysis Two reviewers independently extracted the data. Results from the trials were combined to calculate relative risks (RRs) or risk differences for dichotomous outcomes and weighted mean differences (WMDs) for continuous outcomes, together with 95% CIs. Main results Ten trials were included, involving 1660 women. Generally, the methodological quality was poor. There were no statistically significant differences, comparing MVA with EVA, in complete abortion rate (RR 1.00; 95% CI 0.99-1.02) and participants' satisfaction (RR 1.02; 95% CI 0.87-1.20). In participants with less than 50 days of gestational age, less blood loss (WMD -1.84; 95% CI -2.45 to -1.23) and less severe pain perception (RR 0.04; 95% CI 0.01-0.12) were reported during the MVA procedure, whereas the operation time was shorter (WMD 0.32; 95% CI 0.02-0.6…

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2007.01572.x

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Operation time was shorter for electric vacuum aspiration than for MVA.

    “There was no significant difference in complete abortion rate and participants' satisfaction, whereas the operation time was shorter for electric vacuum aspiration (36).”

    From Unsafe abortion and postabortion care - an overview (2011) · cites this paper as [36]

  • A meta-analysis found no significant difference in complete abortion rate and participants' satisfaction between MVA and electric vacuum aspiration.

    “There was no significant difference in complete abortion rate and participants' satisfaction, whereas the operation time was shorter for electric vacuum aspiration (36).”

    From Unsafe abortion and postabortion care - an overview (2011) · cites this paper as [36]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 27 · Cited by 96

Authors
Wen, J., Cai, Q., Deng, F., & Li, Y.
Affiliations
  • West China Hospital of Sichuan University (CN)
  • Sichuan University (CN)
Corresponding author
Li, YP
ORCID
Wen, J
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2007-12-06
Volume
115
Issue
1
Pages
5-13
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2060041171
Cited by
96
References
27
Citations by year
2026: 1 · 2024: 5 · 2023: 7 · 2022: 4 · 2021: 5 · 2020: 2 · 2019: 5 · 2018: 6 · 2017: 18 · 2016: 5 · 2015: 3 · 2014: 6 · 2013: 4 · 2012: 5
FWCI
0.48
Type
journal article
Language
en
Open access
closed
Locations
  • BJOG An International Journal of Obstetrics & Gynaecology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Reproductive Health and Contraception
  • Health Sciences › Medicine › Obstetrics and Gynecology › Maternal and Perinatal Health Interventions
  • Social Sciences › Political Science and International Relations › International Human Rights and Reproductive Law
Keywords
manual vacuum aspiration, first-trimester abortion, abortion, complete abortion rate, uterine perforation, blood loss, pain perception, patient acceptability, operative time
MeSH terms
Abortion, Induced, Female, Postpartum Hemorrhage, Humans, Pain, Pregnancy, Pregnancy Trimester, First, Vacuum Curettage, Vacuum Extraction, Obstetrical, Randomized Controlled Trials as Topic, Patient Satisfaction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review