Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record.

Maternal complications and pregnancy outcome in women with mechanical prosthetic heart valves treated with enoxaparin

Open access
McLintock, C, McCowan, LME, North, RA · 2009 · BJOG: An International Journal of Obstetrics & Gynaecology

Abstract

Objective To determine maternal and fetal outcomes in women with mechanical heart valves managed with therapeutic dose enoxaparin during pregnancy. Design Retrospective audit. Setting Hospital‐based high‐risk antenatal clinics. Population Pregnant women with mechanical heart valves attending high‐risk antenatal clinics, treated with enoxaparin (1 mg/kg twice daily) during pregnancy. Methods Women with mechanical heart valves treated with enoxaparin at any stage during pregnancy (1997–2008) identified using a database of women with mechanical heart valves attending the high‐risk clinics and a prospective database of women prescribed enoxaparin for any indication during pregnancy. Main outcome measures Maternal outcomes included thromboembolic and haemorrhagic complications. Pregnancy and fetal outcomes included miscarriage, stillbirth, baby death and live birth, small‐for‐gestational‐age infants, warfarin embryopathy and warfarin‐related fetal loss. Results Thirty‐one women underwent 47 pregnancies. In 34 pregnancies (72.3%), anticoagulation was with predominantly enoxaparin and 13 (27.7%) pregnancies women received mainly warfarin, with enoxaparin given in the first trimester and/or peri‐delivery. Seven (14.9%) thrombotic complications occurred, of which five (10.6%) were associated with enoxaparin treatment. Non‐compliance or sub‐therapeutic anti‐Xa levels contributed in each case. Antenatal and postpartum haemorrhagic complications occurred in eight (17%) and 15 (32%) pregnancies respectively. Of 35 pregnancies continuing after 20 weeks’ gestation, 96% (22/23) of women taking predominantly enoxaparin had a surviving infant compared with 75% (9/12) in women taking primarily warfarin. Four perinatal deaths occurred, three attributable to warfarin. Conclusions Compliance with therapeutic dose enoxaparin and aspirin during pregnancy in women with mechanical heart valves is associated with a low risk of valve thrombosis and good fetal outcomes, but close monitoring is essential.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2009.02299.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
McLintock, C., McCowan, L., & North, R.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2009-10-09
Volume
116
Issue
12
Pages
1585-1592
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W1553274174
Cited by
170
References
0
FWCI
7.32
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Maternal complications and pregnancy outcome in women with mechanical prosthetic heart valves treated with enoxaparin. https://app.cochat.ai/papers/10.1111/j.1471-0528.2009.02299.x
The paper
McLintock, C., McCowan, L., & North, R. (2009). Maternal complications and pregnancy outcome in women with mechanical prosthetic heart valves treated with enoxaparin. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2009.02299.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.