CoChat

Impact of mode of delivery on levator morphology: a prospective observational study with three‐dimensional ultrasound early in the postpartum period

Open access
Albrich, SB, Laterza, RM, Skala, C, Salvatore, S, Koelbl, H, Naumann, G · 2012 · BJOG: An International Journal of Obstetrics & Gynaecology
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Please cite this paper as: Albrich S, Laterza R, Skala C, Salvatore S, Koelbl H, Naumann G. Impact of mode of delivery on levator morphology: a prospective observational study with three‐dimensional ultrasound early in the postpartum period. BJOG 2012;119:51–61. Objective To evaluate morphology and integrity of the levator ani muscle (LAM) with three‐dimensional ultrasound early in the postpartum period. Design Prospective cross‐sectional observational study. Setting University hospital in Germany. Population Women after vaginal delivery and caesarean section with no previous vaginal delivery. Methods Three‐dimensional perineal ultrasound was performed between 48 and 72 hours postpartum. The axial plane at the level of minimal hiatal dimension and tomographic ultrasound imaging were used to determine LAM biometry and defect. Main outcome measures Primary outcome was to compare hiatal dimensions and levator defect following vaginal delivery or caesarean section. For secondary outcomes, we evaluated the role of caesarean section in protecting levator integrity, and the possible involvement of the first stage of labour in LAM changes. Results In all, 157 women participated: 81 (51.6%) following vaginal delivery (70 spontaneous and 11 operative deliveries) and 76 (48.4%) following caesarean section (55 elective and 21 emergency caesarean sections). All biometric indices of the levator were higher after vaginal delivery (P < 0.001), except for LAM thickness. LAM defects were found to be significantly associated with vaginal delivery, with relative risk 7.5 (P < 0.001). Following vaginal delivery, 32 (39.5%) levator defects were found: 27 (38.5%) after spontaneous delivery and five (45.4%) after operative delivery. Four (5.2%) women had a levator defect following emergency caesarean section. Conclusion Vaginal delivery modifies and damages the LAM: the risk of levator defect after vaginal delivery is more than seven times higher than after caesarean section. Despite this, emergency caesarean section seems to have no complete preventive effect on LAM trauma.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2011.03152.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 123

Metadata

Authors
Albrich, S., Laterza, R., Skala, C., Salvatore, S., Koelbl, H., & Naumann, G.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2011-10-10
Volume
119
Issue
1
Pages
51-61
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W1492874139
Cited by
123
References
2
FWCI
8.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of mode of delivery on levator morphology: a prospective observational study with three‐dimensional ultrasound early in the postpartum period. https://app.cochat.ai/papers/10.1111/j.1471-0528.2011.03152.x
The paper
Albrich, S., Laterza, R., Skala, C., Salvatore, S., Koelbl, H., & Naumann, G. (2012). Impact of mode of delivery on levator morphology: a prospective observational study with three‐dimensional ultrasound early in the postpartum period. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2011.03152.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.