CoChat

Simultaneous Determination of Serotonin, 5‐Hydroxyindoleacetic Acid, 3,4‐Dihydroxyphenylacetic Acid and Homovanillic Acid by High Performance Liquid Chromatography with Electrochemical Detection

Sperk, Günther · 1982 · Journal of Neurochemistry
Cited by 136

The DOI matches its Crossref record.

Abstract

A rapid and highly sensitive procedure for simultaneous determination of serotonin, 5‐hydroxyindoleacetic acid, 3,4‐dihydroxyphenylacetic acid and homovanillic acid is described. After precipitation of proteins with perchloric acid the samples are applied directly to a high performance liquid chromatograph, with electrochemical detection. As little as 20 pg of serotonin, 5‐hydroxyindoleacetic acid, and 3,4‐dihydroxyphenylacetic acid and 200 pg of homovanillic acid can be detected. One chromatographic run requires less than 10 min.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-4159.1982.tb08708.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 136

Metadata

Authors
Sperk, G.
Venue
Journal of Neurochemistry
Publisher
Wiley
Published
1982-03
Volume
38
Issue
3
Pages
840-843
ISSN
  • 0022-3042 (ISSN-L)
  • 1471-4159
OpenAlex
W1993331018
Cited by
136
References
0
FWCI
9.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Determination of Serotonin, 5‐Hydroxyindoleacetic Acid, 3,4‐Dihydroxyphenylacetic Acid and Homovanillic Acid by High Performance Liquid Chromatography with Electrochemical Detection. https://app.cochat.ai/papers/10.1111/j.1471-4159.1982.tb08708.x
The paper
Sperk, G. (1982). Simultaneous Determination of Serotonin, 5‐Hydroxyindoleacetic Acid, 3,4‐Dihydroxyphenylacetic Acid and Homovanillic Acid by High Performance Liquid Chromatography with Electrochemical Detection. Journal of Neurochemistry. https://doi.org/10.1111/j.1471-4159.1982.tb08708.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.