A simple and fast method for determining colony forming units
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
AIMS: To develop a flexible and fast colony forming unit quantification method that can be operated in a standard microbiology laboratory. METHODS AND RESULTS: A miniaturized plating method is reported where droplets of bacterial cultures are spotted on agar plates. Subsequently, minicolony spots are imaged with a digital camera and quantified using a dedicated plug-in developed for the freeware program IMAGEJ. A comparison between conventional and minicolony plating of industrial micro-organisms including lactic acid bacteria, Eschericha coli and Saccharomyces cerevisiae showed that there was no significant difference in the results obtained with the methods. CONCLUSIONS: The presented method allows downscaling of plating by 100-fold, is flexible, easy-to-use and is more labour-efficient and cost-efficient than conventional plating methods. SIGNIFICANCE AND IMPACT OF THE STUDY: The method can be used for rapid assessment of viable counts of micro-organisms similar to conventional plating using standard laboratory equipment. It is faster and cheaper than conventional plating methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The latter case would result in an underestimation of cell density [19].”
From Rapid growth rate of Enterobacter sp. SM3 determined using several methods (2024) · cites this paper as [19]
Citations
Cites
Simplified Agar Plate Method for Quantifying Viable Bacteria
Jett, B. D., Hatter, K. L., Huycke, M. M., & Gilmore, M. S. (1997) · BioTechniques · doi:10.2144/97234bm22 · Cited by 567 · cited 5×
“From the standard deviations in Table 1, it can be concluded that the sensitivity of the fast method is comparable to the conventional method, although the variation between counts may differ with the type of pipettes used, as argued previously by Jett et al. (1997).”
BackgroundMethodInfluentialHaarman, M., & Knol, J. (2006) · Applied and Environmental Microbiology · doi:10.1128/aem.72.4.2359-2365.2006 · Cited by 321 · cited 4×
“Neeley, E.T., Phister, T.G. and Mills, D.A. (2005) Differential real-time PCR assay for enumeration of lactic acid bacteria in wine.”
BackgroundMethodInfluentialSpiral Plate Method for Bacterial Determination
Gilchrist, J. E., Campbell, J. E., Donnelly, C. B., Peeler, J. T., & Delaney, J. M. (1973) · Applied Microbiology · doi:10.1128/am.25.2.244-252.1973 · Cited by 224 · cited 4×
“…275–278 275 that is not present in standard microbiology laboratories (Gilchrist et al. 1973; Liu et al. 2004b), may result only in limited downscaling (Gilchrist et al. 1973; Jett et al. 1997; Hamilton et al. 2002), or are poorly suited for automation (McNulty and Dunn 1999; Hamilton et al.…”
BackgroundInfluentialLay, C., Sutren, M., Rochet, V., Saunier, K., Doré, J., & Rigottier‐Gois, L. (2005) · Environmental Microbiology · doi:10.1111/j.1462-2920.2005.00763.x · Cited by 166 · cited 1×
“In recent years a range of alternative, high-throughput (HT), methods relying on quantitative PCR (Neeley et al. 2005; Haarman and Knol 2006), fluorescent labelling (Blasco et al. 2003; Lay et al. 2005) or genome probing with micro arrays (Bae et al. 2005) have gained popularity (Liu et al. 2004a).”
BackgroundA high‐throughput method for quantifying growth of phytopathogenic bacteria in Arabidopsis thaliana
Tornero, P., & Dangl, J. L. (2001) · The Plant Journal · doi:10.1046/j.1365-313x.2001.01136.x · Cited by 162 · cited 1×
“Several reports describe alternative plating technologies in which the required volumes are down-scaled (Jett et al. 1997; McNulty and Dunn 1999; Tornero and Dangl 2001; Hamilton et al. 2002) or the colony counting process is automated (Marotz et al. 2001; Dahle et al. 2004; Putman et al. 2005).”
BackgroundTechnological Advances in High-Throughput Screening
Liu, B., Li, S., & Hu, J. (2004) · American Journal of PharmacoGenomics · doi:10.2165/00129785-200404040-00006 · Cited by 153 · cited 4×
“Moreover, growing many colonies on a relatively small surface area results in smaller colonies for instance due to limited substrate availability (Liu et al. 2004b).”
BackgroundInfluentialBlasco, L., Ferrer, S., & Pardo, I. (2003) · FEMS Microbiology Letters · doi:10.1016/s0378-1097(03)00501-9 · Cited by 119 · cited 2×
“2005; Haarman and Knol 2006), fluorescent labelling (Blasco et al. 2003; Lay et al. 2005) or genome probing with micro arrays (Bae et al.”
BackgroundDevelopment and Evaluation of Genome-Probing Microarrays for Monitoring Lactic Acid Bacteria
Bae, J.-W., Rhee, S.-K., Park, J. R., Chung, W.-H., Nam, Y.-D., Lee, I., Kim, H., & Park, Y.-H. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.12.8825-8835.2005 · Cited by 115 · cited 2×
“2005) or genome probing with micro arrays (Bae et al. 2005) have gained popularity (Liu et al.”
BackgroundDifferential Real-Time PCR Assay for Enumeration of Lactic Acid Bacteria in Wine
Neeley, E. T., Phister, T. G., & Mills, D. A. (2005) · Applied and Environmental Microbiology · doi:10.1128/aem.71.12.8954-8957.2005 · Cited by 77 · cited 4×
“Neeley, E.T., Phister, T.G. and Mills, D.A. (2005) Differential real-time PCR assay for enumeration of lactic acid bacteria in wine.”
BackgroundMethodInfluentialMarotz, J., Lübbert, C., & Eisenbeiß, W. (2001) · Computer Methods and Programs in Biomedicine · doi:10.1016/s0169-2607(00)00128-0 · Cited by 73 · cited 2×
“2002) or the colony counting process is automated (Marotz et al. 2001; Dahle et al. 2004; Putman et al. 2005).”
BackgroundMethodAutomated counting of mammalian cell colonies by means of a flat bed scanner and image processing
Dahle, J., Kakar, M., Steen, H. B., & Kaalhus, O. (2004) · Cytometry Part A · doi:10.1002/cyto.a.20038 · Cited by 69 · cited 3×
“2002) or the colony counting process is automated (Marotz et al. 2001; Dahle et al. 2004; Putman et al. 2005).”
BackgroundMethodSimplified method to automatically count bacterial colony forming unit
Putman, M., Burton, R. L., & Nahm, M. H. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.05.003 · Cited by 68 · cited 2×
“Also several HT alternatives for counting of CFU are reported (Dahle et al. 2004; Liu et al. 2004b; Putman et al. 2005).”
BackgroundColony counting is a major source of variation in CFU‐GM results between centres
Lumley, M., Burgess, R., Billingham, L. J., McDonald, D., & Milligan, D. W. (1997) · British Journal of Haematology · doi:10.1046/j.1365-2141.1997.492695.x · Cited by 50 · cited 2×
“Because the counting is partially automated, the user can monitor critical steps in data acquisition and processing without the variability encountered from manual counting of CFUs (Lumley et al. 1997).”
MethodLiu, X., Wang, S., Sendi, L., & Caulfield, M. J. (2004) · Journal of Immunological Methods · doi:10.1016/j.jim.2004.06.021 · Cited by 46 · cited 4×
“Moreover, growing many colonies on a relatively small surface area results in smaller colonies for instance due to limited substrate availability (Liu et al. 2004b).”
BackgroundInfluentialMultichannel Plating Unit for High-Throughput Plating of Cell Cultures
Hamilton, C. M., Anderson, M., Lape, J., Creech, E. M. H., & Woessner, J. P. (2002) · BioTechniques · doi:10.2144/02332ht02 · Cited by 8 · cited 5×
“2004b), may result only in limited downscaling (Gilchrist et al. 1973; Jett et al. 1997; Hamilton et al. 2002), or are poorly suited for automation (McNulty and Dunn 1999; Hamilton et al.”
BackgroundInfluentialHigh-Throughput Transformation and Plating Using Petristrips
McNulty, J. J., & Dunn, J. J. (1999) · BioTechniques · doi:10.2144/99263bm04 · Cited by 4 · cited 4×
“Several reports describe alternative plating technologies in which the required volumes are down-scaled (Jett et al. 1997; McNulty and Dunn 1999; Tornero and Dangl 2001; Hamilton et al. 2002) or the colony counting process is automated (Marotz et al.”
BackgroundInfluential
Cited by
A review of methods for the detection of pathogenic microorganisms
Rajapaksha, P., Elbourne, A., Gangadoo, S., Brown, R., Cozzolino, D., & Chapman, J. (2019) · The Analyst · doi:10.1039/c8an01488d · Cited by 588
OpenCFU, a New Free and Open-Source Software to Count Cell Colonies and Other Circular Objects
Geissmann, Q. (2013) · PLoS ONE · doi:10.1371/journal.pone.0054072 · Cited by 385
Thomas, P., Sekhar, A. C., Upreti, R., Mujawar, M. M., & Pasha, S. S. (2015) · Biotechnology Reports · doi:10.1016/j.btre.2015.08.003 · Cited by 323
Antibacterial Liquid Metals: Biofilm Treatment via Magnetic Activation
Elbourne, A., Cheeseman, S., Atkin, P., Truong, N. P., Syed, N., Zavabeti, A., Mohiuddin, M., Esrafilzadeh, D., Cozzolino, D., McConville, C. F., et al. (2020) · ACS Nano · doi:10.1021/acsnano.9b07861 · Cited by 302
The no-SCAR (Scarless Cas9 Assisted Recombineering) system for genome editing in Escherichia coli
Reisch, C. R., & Prather, K. L. J. (2015) · Scientific Reports · doi:10.1038/srep15096 · Cited by 251
Metadata
- Authors
- Sieuwerts, S., de Bok, F. A. M., Mols, E., de Vos, W. M., & van Hylckama Vlieg, J. E. T.
- Venue
- Letters in Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-10
- Volume
- 47
- Issue
- 4
- Pages
- 275-278
- ISSN
- 0266-8254 (ISSN-L)
- 1472-765X
- OpenAlex
- W2068536139
- Cited by
- 222
- References
- 16
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- green
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 2526 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.