Sterilization effect of atmospheric plasma on Escherichia coli and Bacillus subtilis endospores
The DOI matches its Crossref record.
Abstract
AIMS: Escherichia coli and Bacillus subtilis spores were treated with an atmospheric plasma mixture created by the ionization of helium and oxygen to investigate the inactivation efficiency of a low-temperature plasma below 70 degrees C. METHODS AND RESULTS: An electrical discharge plasma was produced at a radio frequency (RF) of 13.56 MHz, connected to a perforated circular electrode with a discharge spacing of 1-15 mm. The discharge gas was helium with 0-2% oxygen. For the plasma treatment, a dried E. coli cell or B. subtilis endospore suspension on a cover-glass was exposed to oxygen downstream of the plasma from holes in an RF-powered electrode. The sterilization effect of the RF plasma was highest with 0.2% oxygen, corresponding to the maximum production of oxygen radicals. CONCLUSIONS: Oxygen radicals generated by RF plasma are effective for the destruction of bacterial cells and endospores. SIGNIFICANCE AND IMPACT OF THE STUDY: Low-temperature atmospheric plasma can be used for the disinfection of diverse objects, especially for the inactivation of bacterial endospores.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nonthermal Plasma Inactivation of Food-Borne Pathogens
Misra, N. N., Tiwari, B. K., Raghavarao, K. S. M. S., & Cullen, P. J. (2011) · Food Engineering Reviews · doi:10.1007/s12393-011-9041-9 · Cited by 599
Inactivation mechanisms of non-thermal plasma on microbes: A review
Liao, X., Liu, D., Xiang, Q., Ahn, J., Chen, S., Ye, X., & Ding, T. (2017) · Food Control · doi:10.1016/j.foodcont.2016.12.021 · Cited by 512
Non-Thermal Atmospheric-Pressure Plasma Possible Application in Wound Healing
Haertel, B., Woedtke, T. V., Weltmann, K.-D., & Lindequist, U. (2014) · Biomolecules & Therapeutics · doi:10.4062/biomolther.2014.105 · Cited by 433
Cold Atmospheric Plasma: methods of production and application in dentistry and oncology
Hoffmann, C., Berganza, C., & Zhang, J. (2013) · Medical Gas Research · doi:10.1186/2045-9912-3-21 · Cited by 412
The plasma jet kINPen – A powerful tool for wound healing
Bekeschus, S., Schmidt, A., Weltmann, K.-D., & von Woedtke, T. (2016) · Clinical Plasma Medicine · doi:10.1016/j.cpme.2016.01.001 · Cited by 390
Metadata
- Authors
- Hong, Y. F., Kang, J. G., Lee, H. Y., Uhm, H. S., Moon, E., & Park, Y. H.
- Venue
- Letters in Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-01
- Volume
- 48
- Issue
- 1
- Pages
- 33-37
- ISSN
- 0266-8254 (ISSN-L)
- 1472-765X
- OpenAlex
- W2042925861
- Cited by
- 114
- References
- 0
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sterilization effect of atmospheric plasma on Escherichia coli and Bacillus subtilis endospores. https://app.cochat.ai/papers/10.1111/j.1472-765x.2008.02480.x
- The paper
- Hong, Y. F., Kang, J. G., Lee, H. Y., Uhm, H. S., Moon, E., & Park, Y. H. (2009). Sterilization effect of atmospheric plasma on Escherichia coli and Bacillus subtilis endospores. Letters in Applied Microbiology. https://doi.org/10.1111/j.1472-765x.2008.02480.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.