CoChat

Repeatability of fibre type and enzyme activity measurements in human skeletal muscle

Simoneau, J.‐A., Lortie, G., Boulay, M. R., Thibault, M.‐C., Bouchard, C. · 1986 · Clinical Physiology
Cited by 56

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Summary. In order to assess the variability in repeated determination of human muscle fibre type distribution, fibre area and enzyme activity measurements, two biopsies were taken within 10 days in the same vastus lateralis for 12 females and 13 males, and in the right and in the left muscles for 25 other subjects (13 females and 12 males). Within muscle, intraclass reliability coefficients were 0·88, 0·82 and 0·56 for type I, IIa and IIb per cent fibres, respectively, and ranged from 0·74 to 0·82 for fibre areas and from 0·71 to 0·90 for enzyme markers of different metabolic pathways. Correlations between right and left muscle measurements were also high for fibre areas (from 0·85 to 0·91) and enzyme activities (from 0·71 to 0·87), except for phosphofructokinase (r=0·63). In contrast, the right and left thigh muscle correlation reached 0·67, 0·40 and 0·64 for type I, IIa and IIb fibre distribution, respectively. Thus, the variation in muscle sampling and technical procedures reached about 15% of the total variation (i.e. total differences between subjects) for the proportion of fibre type I and IIa and about 20–25% for fibre areas and enzyme activities. On the other hand, the technical error for the proportion of fibre type I and IIa is about 6–7%. This implies that differences brought about by any experimental treatment on these skeletal muscle characteristics in human studies have to be of a relatively large magnitude before being detectable. On the other hand, fibre areas and enzyme activities measured in single needle biopsy sample, from one of the vastus lateralis muscles, are quite representative of the other vastus lateralis. Similarity in fibre type proportion between right and left vastus lateralis cannot be postulated, however, without investigating both muscles.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-097x.1986.tb00240.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 56

Metadata

Authors
Simoneau, J. ‐., Lortie, G., Boulay, M. R., Thibault, M. ‐., & Bouchard, C.
Venue
Clinical Physiology
Publisher
Wiley
Published
1986-08
Volume
6
Issue
4
Pages
347-356
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W1984429599
Cited by
56
References
3
FWCI
1.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability of fibre type and enzyme activity measurements in human skeletal muscle. https://app.cochat.ai/papers/10.1111/j.1475-097x.1986.tb00240.x
The paper
Simoneau, J. ‐., Lortie, G., Boulay, M. R., Thibault, M. ‐., & Bouchard, C. (1986). Repeatability of fibre type and enzyme activity measurements in human skeletal muscle. Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1986.tb00240.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.