CoChat

Comparison of three methods for detection of the lactate threshold

Davis, James A., Rozenek, Ralph, DeCicco, Derek M., Carizzi, Michael T., Pham, Patrick H. · 2007 · Clinical Physiology and Functional Imaging
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Summary: The lactate threshold (LT) represents the onset of a metabolic acidosis during graded exercise testing (GXT). It is a valuable measurement in clinical exercise testing and correlates well with endurance performance. Our purpose was to compare three LT detection methods, namely, Inspection (work rate at onset of a systematic increase in blood lactate concentration determined by inspection of blood lactate versus work rate plot), 0·5 mM (work rate which just precedes a rise in blood lactate concentration of >0·5 mM) and log–log (work rate at the intersection of two linear lines in plot of log lactate versus log work rate where the residual sum of squares for both lines added together is minimized). Fourteen subjects underwent cycle ergometer GXT with blood samples obtained at the end of each 3‐min work rate increment and analysed for lactate concentration. The mean ± 95% confidence limits of work rates at LT for the Inspection, 0·5 mM and log–log methods were 104·5 ± 28·0, 103·2 ± 28·1 and 105·1 ± 27·3 W, respectively. Repeated‐measures analysis of variance yielded a non‐significant F ratio. The Bland–Altman bias ± 95% limits of agreement for Inspection versus 0·5 mM, Inspection versus log‐log and 0·5 mM versus log–log were 1·3 ± 20·6, −0·6 ± 12·5 and −1·9 ± 20·5 W, respectively. The intraclass correlation coefficients for Inspection versus 0·5 mM, Inspection versus log–log and 0·5 mM versus log–log were 0·978, 0·992 and 0·977, respectively. The results of this study suggest that all three methods detect the LT at the same work rate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-097x.2007.00762.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 46

Metadata

Authors
Davis, J. A., Rozenek, R., DeCicco, D. M., Carizzi, M. T., & Pham, P. H.
Venue
Clinical Physiology and Functional Imaging
Publisher
Wiley
Published
2007-08-31
Volume
27
Issue
6
Pages
381-384
ISSN
  • 1475-0961 (ISSN-L)
  • 1475-097X
OpenAlex
W1995068344
Cited by
46
References
1
FWCI
2.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of three methods for detection of the lactate threshold. https://app.cochat.ai/papers/10.1111/j.1475-097x.2007.00762.x
The paper
Davis, J. A., Rozenek, R., DeCicco, D. M., Carizzi, M. T., & Pham, P. H. (2007). Comparison of three methods for detection of the lactate threshold. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/j.1475-097x.2007.00762.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.