The combination of a blood test and Fibroscan improves the non‐invasive diagnosis of liver fibrosis
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background and aims: Blood tests and liver stiffness evaluation (LSE) by ultrasonographic elastometry are accurate tools for diagnosing liver fibrosis. We evaluated whether their synchronous combination in new scores could improve the diagnostic accuracy and reduce liver biopsy requirement in algorithm. Methods: Three hundred and ninety patients with chronic liver disease of miscellaneous causes were included. Five blood fibrosis tests were evaluated: APRI, FIB‐4, Hepascore, Fibrotest and FibroMeter. The reference was fibrosis Metavir staging. Results: Diagnosis of significant fibrosis (Metavir F≥2). The most accurate synchronous combination was FibroMeter+LSE, which provided a significantly higher area under the receiver operating characteristic curve (0.892) than LSE alone (0.867, P=0.011) or Fibrometer (0.834, P<10−3). An algorithm using the FibroMeter+LSE combination and then a liver biopsy in indeterminate cases had 91.9% diagnostic accuracy and required significantly fewer biopsies (20.2%) than previously published Bordeaux algorithm (28.6%, P=0.02) or sequential algorithm for fibrosis evaluation (SAFE) (55.7%, P<10−3). The Angers algorithm performance was not significantly different between viral hepatitis and other causes. Diagnosis of cirrhosis. The most accurate synchronous combination was LSE+FibroMeter, which provided ≥90% predictive values for cirrhosis in 90.6% of patients vs 87.4% for LSE (P=0.02) and 57.9% for FibroMeter (P<10−3). An algorithm including the LSE+FibroMeter combination, and then a liver biopsy in indeterminate cases, had a significantly higher diagnostic accuracy than the SAFE algorithm (91.0 vs 79.8%, P<10−3), and required significantly fewer biopsies than the Bordeaux algorithm (9.3 vs 25.3%, P<10−3). Conclusion: The synchronous combination of a blood test plus LSE improves the accuracy of the non‐invasive diagnosis of liver fibrosis and, consequently, markedly decreases the biopsy requirement in the diagnostic algorithm, notably to <10% in cirrhosis diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sterling, R. K., Lissen, E., Clumeck, N., Sola, R., Correa, M. C., Montaner, J., S. Sulkowski, M., Torriani, F. J., Dieterich, D. T., Thomas, D. L., et al. (2006) · Hepatology · doi:10.1002/hep.21178 · Cited by 5,021 · cited 4×
“The first generation of simple blood tests combined common indirect fibrosis markers into a simple ratio, like APRI (4) and FIB-4 (5).”
BackgroundInfluentialWai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124 · cited 1×
“21, all LSE were included in the statistical analysis according to the ‘intention-to-diagnose’ principle (31).”
Method
Cited by
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
“Since the first proposal of a strategy combining TE and FibroTest! to increase diagnostic accuracy in patients with hepatitis C [126], many algorithms combining either TE and serum biomarkers [125,143,198–200,202,204,205] or several serum biomarkers [122,206–210] have been proposed, mainly in patients with viral hepat…”
BackgroundFerraioli, G., Wong, V. W.-S., Castera, L., Berzigotti, A., Sporea, I., Dietrich, C. F., Choi, B. I., Wilson, S. R., Kudo, M., & Barr, R. G. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2018.07.008 · Cited by 574
Jeng, W.-J., Papatheodoridis, G. V., & Lok, A. S. F. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01468-4 · Cited by 561
Imaging the elastic properties of tissue: the 20 year perspective
Parker, K. J., Doyley, M. M., & Rubens, D. J. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/1/r01 · Cited by 477
Liver stiffness: a novel parameter for the diagnosis of liver disease
Mueller, S. (2010) · Hepatic Medicine: Evidence and Research · doi:10.2147/hmer.s7394 · Cited by 434
“Although serum markers that are used within scores such as the Fibrotest, APRI score, etc, are widely explored and have been also cross-validated with FS, 22,35,50–54 the authors, up to now, do not generally recommend their use and FS seems to outscore all of these tests.”
Influential
Metadata
- Authors
- Boursier, J., Vergniol, J., Sawadogo, A., Dakka, T., Michalak, S., Gallois, Y., Le Tallec, V., Oberti, F., Fouchard‐Hubert, I., Dib, N., Rousselet, M. C., Konaté, A., Amrani, N., De Ledinghen, V., & Calès, P.
- Venue
- Liver International
- Publisher
- Wiley
- Published
- 2009-10
- Volume
- 29
- Issue
- 10
- Pages
- 1507-1515
- ISSN
- 0106-9543 (ISSN-L)
- 1478-3223
- 1478-3231
- OpenAlex
- W2101673499
- Cited by
- 118
- References
- 3
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.