CoChat

The Impact of Polyethylene Glycol Conjugation on Bovine Hemoglobin's Circulatory Half‐Life and Renal Effects in a Rabbit Top‐Loaded Transfusion Model

Conover, Charles D., Gilbert, Carl W., Shurn, Kwok L., Shorr, Robert G.L. · 1997 · Artificial Organs
Cited by 35

The DOI matches its Crossref record.

Abstract

This study compares the effects of polyethylene glycol (PEG) modified bovine hemoglobin on vascular half‐life and renal function in rabbits to those of unmodi fied bovine hemoglobin. Renal function was assessed by the measurement of the glomerular filtration rate, urinalysis, blood chemistries, hemoglobin (Hb) excretion rates, and tissue histology. The influence of infusion rates on hemoglobin excretion rates and organ morphology was also examined. The mean half‐life of unmodified bovine hemoglobin was 3.0 ± 0.1 (mean ± SEM) h, which was extended 14‐fold to 43.2 ± 1.7 h following PEG conjugation. The glomerular filtration rate, urinalysis, and blood chemistries were not greatly affected by either the un modified bovine hemoglobin or the PEG modified bovine hemoglobin. However, unmodified bovine hemoglobin did demonstrate significant hemoglobinuria (Hb excretion levels in excess of 1.0% of the infused dose [p < 0.051) at all infusion rates given while PEG modified bovine hemoglobin did not. In addition, histological examination by light microscopy indicated that the most severe morphological changes occurred in animals that received unmodified bo vine hemoglobin. This data suggests that PEG modification of bovine hemoglobin significantly reduced some of the adverse effects of bovine hemoglobin on renal physiology and morphology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.1997.tb00250.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Conover, C. D., Gilbert, C. W., Shurn, K. L., & Shorr, R. G. L.
Venue
Artificial Organs
Publisher
Wiley
Published
1997-08
Volume
21
Issue
8
Pages
907-915
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W1965889970
Cited by
35
References
0
FWCI
0.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.