CoChat

Effect of Polyethylene Glycol Conjugated Bovine Hemoglobin in Both Top‐Load and Exchange Transfusion Rat Models

Conover, Charles D., Linberg, Rita, Gilbert, Carl W., Shum, Kwok L., Shorr, Robert G.L. · 1997 · Artificial Organs
Cited by 35

The DOI matches its Crossref record.

Abstract

The purpose of this study was to determine the effect of the hemoglobin based oxygen carrier, polyethylene glycol conjugated bovine hemoglobin (PEG‐Hb) on the physiology of the rat. This study was divided into the following 3 parts: pharmacokinetics, cardiovascular, and histopathology. Pharmacokinetic studies evaluated the PEG‐Hb circulatory life and the resultant effect on urine composition. Telemetric intravascular blood pressure probes monitored the heart rate and mean arterial pressure. Renal arterial blood flow was determined by intra‐operative perivascular ultrasound. Tissue histology was evaluated for both time and model dependent responses. The mean circulatory half‐life of PEG‐Hb was 17.7 ± 0.3 h. Proteinuria and hemoglobinuria were greatly reduced with PEG conjugation. PEG‐Hb treated rats produced 8.5 times and 49 times less proteinuria and hemoglobinuria, respectively, than unmodified bovine Hb treated animals. The mean arterial pressure (MAP) in PEG‐Hb treated rats was insignificantly different from sham controls undergoing a 30% exchange transfusion while dextran caused an initial reduction and bovine Hb produced a prolonged elevation in the MAP. In these same anesthetized rats. PEG‐Hb slightly decreased the heart rate while dextran caused an increase and bovine Hb had no effect. In addition, PEG‐Hb was able to maintain the renal arterial blood flow while both Ringer's lactate and bovine Hb caused a reduction in the blood flow. Finally, PEG‐Hb treated rats showed a dose and time dependent formation of vacuoles within the renal proximal convoluted tubules and splenic macrophages in both top‐load and exchange transfusion models, but no other morphological changes. In conclusion, PEG‐Hb had a relatively long vascular persistence that did not cause any significant alterations in the urinalysis, cardiovascular function, or tissue histopathology in the rat.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.1997.tb00444.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Conover, C. D., Linberg, R., Gilbert, C. W., Shum, K. L., & Shorr, R. G. L.
Venue
Artificial Organs
Publisher
Wiley
Published
1997-10
Volume
21
Issue
10
Pages
1066-1075
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2109461041
Cited by
35
References
0
FWCI
1.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of Polyethylene Glycol Conjugated Bovine Hemoglobin in Both Top‐Load and Exchange Transfusion Rat Models. https://app.cochat.ai/papers/10.1111/j.1525-1594.1997.tb00444.x
The paper
Conover, C. D., Linberg, R., Gilbert, C. W., Shum, K. L., & Shorr, R. G. L. (1997). Effect of Polyethylene Glycol Conjugated Bovine Hemoglobin in Both Top‐Load and Exchange Transfusion Rat Models. Artificial Organs. https://doi.org/10.1111/j.1525-1594.1997.tb00444.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.