CoChat

Cerebral and Lower Limb Near‐Infrared Spectroscopy in Adults on Extracorporeal Membrane Oxygenation

Wong, Joshua K., Smith, Thomas N., Pitcher, Harrison T., Hirose, Hitoshi, Cavarocchi, Nicholas C. · 2012 · Artificial Organs
Cited by 194

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Percutaneous femoral venoarterial (VA) or jugular venovenous (VV) extracorporeal membrane oxygenation (ECMO) can result in delivery of hypoxic blood to the brain, coronaries, and upper extremities. Additionally, VA‐ECMO by percutaneous femoral artery cannulation may compromise perfusion to the lower limbs. Use of near‐infrared spectroscopy (NIRS) detects regional ischemia and warns of impending hypoxic damage. We report the first known series with standardized monitoring of this parameter in adults on ECMO. This is an institutional review board‐approved single institution retrospective review of patients with NIRS monitoring on ECMO from July 2010 until June 2011. Patients were analyzed for drops in NIRS tracings below 40 or >25% from baseline. VA‐ECMO and VV‐ECMO were initiated by percutaneous cannulation of the femoral vessels and the internal jugular vein, respectively. Sensors were placed on the patients' foreheads and on the lower limbs. NIRS tracings were recorded, analyzed, and correlated with clinical events. Twenty patients were analyzed (median age: 47.5 years): 17 patients were placed on VA‐ECMO, and three patients on VV‐ECMO. The median duration on ECMO was 7 days (range 2–26). One hundred percent of patients had a significant drop in bilateral cerebral oximetry tracings resulting in hemodynamic interventions, which involved increasing pressure, oxygenation, and/or ECMO flow. In 16 patients (80%), these interventions corrected the underlying ischemia. Four patients (20%) required further diagnostic intervention for persistent decreased bilateral and/or unilateral cerebral oximetry tracings, and were found to have a cerebrovascular accident (CVA). Six (30%) patients had persistent unilateral lower limb oximetry events, which resolved upon placement or replacement of a distal perfusion cannula. No patient was found to have either lower limb ischemia or a CVA with normal NIRS tracings. Use of NIRS with ECMO is important in detecting ischemic cerebral and peripheral vascular events. This allows for potential correction of the underlying process, thus preventing permanent ischemic damage.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.2012.01496.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 194

Metadata

Authors
Wong, J. K., Smith, T. N., Pitcher, H. T., Hirose, H., & Cavarocchi, N. C.
Venue
Artificial Organs
Publisher
Wiley
Published
2012-07-23
Volume
36
Issue
8
Pages
659-667
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2125473090
Cited by
194
References
2
FWCI
6.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.