Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record.

Cortical Afterdischarge and Functional Response Thresholds: Results of Extraoperative Testing

Lesser, R. P., Lüders, H., Klem, G., Dinner, D. S., Morris, H. H., Hahn, J. · 1984 · Epilepsia

Abstract

Summary: We have evaluated the afterdischarge thresholds and functional response thresholds in 21 patients with chronically implanted arrays of subdural electrodes. Afterdischarge thresholds varied from 2 to > 15 mA over the tested cortex, by as much as 12 mA in individual patients, and by as much as 12 mA between adjacent electrodes. Thresholds for functional alteration varied from 2 to 15 mA in tested cortex, by as much as 9.5 mA in individually tested patients, and by as much as 6.5 mA between adjacent electrodes. We conclude that the optimal localization of functional cortical areas requires different stimulation intensities at different points. The use of too high an intensity would produce afterdischarges at some positions. The use of too low an intensity would falsely make others appear functionally “silent.” RESUMEN: Hemos evaluado los umbrales post‐descarga y los umbrales de respuesta funcional en 21 pacientes con series de electrodos subdurales implantados crónicamente. Los umbrales post‐descarga variaron entre 2 y más de 15 miliamperios en la corteza investigada, variaron tan to como 12 miliamperios en pacientes individuales y tanto como 12 miliamperios entre electrodos contíguos. El umbral de la alteración funcional varió de 2 a 15 miliamperios en la corteza explorada, tanto como 9.5 miliamperios en un mismo enfermo y tanto como 6.5 miliamperios entre electrodos contíguos. Hemos concluido que para localizar las áreas funcionales corticales óptimas se requieren diferentes estímulos eléctricos en puntos diversos. La utilización de intensidades demasiado elevadas podría producir post‐descargas en algunas posiciones. El uso de intensidades demasiado bajas haría que otras áreas aparecieran como falsas silentes, funcionalmente. ZUSAMMENFASSUNG: Wir haben bei 21 Patienten mit chronisch implantierten subduralen Elektroden, die Schwelle der Nachentladung und der funktionellen Antwort geprüft. Über dem untersuchten Cortex variierten die Schwellen für die Nachentladung von 2 bis iiber 15 Milliampere; sie variierten innerhalb einzelner Patienten um mehr als 12 Milliampere und zwischen benachbarten Elektroden um etwa 12 Milliampere. Die Schwellenwerte für die funktionellen Veränderungen variierten von 2 bis 15 Milliampere im getesteten Cortex, um 9,5 Milliampere bei einzelnen Individuen und um 6,5 Milliampere zwischen benachbarten Elektroden. Wir folgern daraus, daß die optimale Lokalisation funktioneller kortikaler Areale unterschiedliche Reizintensitäten an unterschiedlichen Punkten erfordert. Die Verwendung zu hoher Intensitäten würde an einzelnen Stellen Nachentladungen hervorrufen. Die Benutzung zu schwacher Intensitäten würde andere Areale fälschlich erweise als stumm ausweisen.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1157.1984.tb03471.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
Lesser, R. P., Lüders, H., Klem, G., Dinner, D. S., Morris, H. H., & Hahn, J.
Venue
Epilepsia
Publisher
Wiley
Published
1984-10
Volume
25
Issue
5
Pages
615-621
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2065524125
Cited by
170
References
0
FWCI
0.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cortical Afterdischarge and Functional Response Thresholds: Results of Extraoperative Testing. https://app.cochat.ai/papers/10.1111/j.1528-1157.1984.tb03471.x
The paper
Lesser, R. P., Lüders, H., Klem, G., Dinner, D. S., Morris, H. H., & Hahn, J. (1984). Cortical Afterdischarge and Functional Response Thresholds: Results of Extraoperative Testing. Epilepsia. https://doi.org/10.1111/j.1528-1157.1984.tb03471.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.