The DOI matches its Crossref record.
How accurate is ICD coding for epilepsy?
Abstract
Summary: Purpose: Assess the validity of ICD‐9‐CM and ICD‐10 epilepsy coding from an emergency visit (ER) and a hospital discharge abstract database (DAD). Methods: Two separate sources of patient records were reviewed and validated. (1) Charts of patients admitted to our seizure monitoring unit over 2 years (n = 127, ICD‐10 coded records) were reviewed. Sensitivity (Sn), specificity (Sp), and positive and negative predictive values (PPV and NPV) were calculated. (2) Random sample of charts for patients seen in the ER or admitted to hospital under any services, and whose charts were coded with epilepsy or an epilepsy‐like condition, were reviewed. Two time‐periods were selected to allow validation of both ICD‐9‐CM (n = 486) and ICD‐10 coded (n = 454) records. Only PPV and NPV were calculated for these records. All charts were reviewed by two physicians to confirm the presence/absence of epilepsy and compare to administrative coding. Results: Sample 1: Sn, Sp, PPV, and NPV of ICD‐10 epilepsy coding from the seizure monitoring unit (SMU) chart review were 99%, 70%, 85%, and 97% respectively. Sample 2: The PPV and NPV for ICD‐9‐CM coding from the ER database were, respectively, 99% and 97% and from the DAD were 98% and 99%. The PPV and NPV for ICD‐10 coding from the ER database were, respectively, 100% and 90% and from the DAD were 98% and 99%. The epilepsy subtypes grand mal status and partial epilepsy with complex partial seizures both had PPVs >75% (ICD‐9‐CM and ICD‐10 data). Discussion: Administrative emergency and hospital discharge data have high epilepsy coding validity overall in our health region.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Standards for epidemiologic studies and surveillance of epilepsy
Thurman, D. J., Beghi, E., Begley, C. E., Berg, A. T., Buchhalter, J. R., Ding, D., Hesdorffer, D. C., Hauser, W. A., Kazis, L., Kobau, R., et al. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03121.x · Cited by 1,014
Self-citationIncidence and Prevalence of Childhood Epilepsy: A Nationwide Cohort Study
Aaberg, K. M., Gunnes, N., Bakken, I. J., Lund Søraas, C., Berntsen, A., Magnus, P., Lossius, M. I., Stoltenberg, C., Chin, R., & Surén, P. (2017) · Pediatrics · doi:10.1542/peds.2016-3908 · Cited by 503
Methods for identifying 30 chronic conditions: application to administrative data
Tonelli, M., Wiebe, N., Fortin, M., Guthrie, B., Hemmelgarn, B. R., James, M. T., Klarenbach, S. W., Lewanczuk, R., Manns, B. J., Ronksley, P., et al. (2016) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-015-0155-5 · Cited by 400
Self-citationRecommendations for optimal ICD codes to study neurologic conditions: A systematic review
St. Germaine-Smith, C., Metcalfe, A., Pringsheim, T., Roberts, J. I., Beck, C. A., Hemmelgarn, B. R., McChesney, J., Quan, H., & Jette, N. (2012) · Neurology · doi:10.1212/wnl.0b013e3182684707 · Cited by 206
Self-citationAccuracy of the ICD-10 discharge diagnosis for syncope
Ruwald, M. H., Hansen, M. L., Lamberts, M., Kristensen, S. L., Wissenberg, M., Olsen, A.-M. S., Christensen, S. B., Vinther, M., Kober, L., Torp-Pedersen, C., et al. (2013) · Europace · doi:10.1093/europace/eus359 · Cited by 79
Metadata
- Authors
- Jetté, N., Reid, A. Y., Quan, H., Hill, M. D., & Wiebe, S.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2009-12-21
- Volume
- 51
- Issue
- 1
- Pages
- 62-69
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1966516148
- Cited by
- 232
- References
- 0
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How accurate is ICD coding for epilepsy? https://app.cochat.ai/papers/10.1111/j.1528-1167.2009.02201.x
- The paper
- Jetté, N., Reid, A. Y., Quan, H., Hill, M. D., & Wiebe, S. (2010). How accurate is ICD coding for epilepsy? Epilepsia. https://doi.org/10.1111/j.1528-1167.2009.02201.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.