The DOI matches its Crossref record.
Methodology of photic stimulation revisited: Updated European algorithm for visual stimulation in the EEG laboratory
Abstract
Summary: Intermittent photic stimulation (IPS) is a common procedure performed in the electroencephalography (EEG) laboratory in children and adults to detect abnormal epileptogenic sensitivity to flickering light (i.e., photosensitivity). In practice, substantial variability in outcome is anecdotally found due to the many different methods used per laboratory and country. We believe that standardization of procedure, based on scientific and clinical data, should permit reproducible identification and quantification of photosensitivity. We hope that the use of our new algorithm will help in standardizing the IPS procedure, which in turn may more clearly identify and assist monitoring of patients with epilepsy and photosensitivity. Our algorithm goes far beyond that published in 1999 (Epilepsia, 1999a, 40, 75; Neurophysiol Clin, 1999b, 29, 318): it has substantially increased content, detailing technical and logistical aspects of IPS testing and the rationale for many of the steps in the IPS procedure. Furthermore, our latest algorithm incorporates the consensus of repeated scientific meetings of European experts in this field over a period of 6 years with feedback from general neurologists and epileptologists to improve its validity and utility. Accordingly, our European group has provided herein updated algorithms for two different levels of methodology: (1) requirements for defining photosensitivity in patients and in family members of known photosensitive patients and (2) requirements for tailored studies in patients with a clear history of visually induced seizures or complaints, and in those already known to be photosensitive.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Specchio, N., Wirrell, E. C., Scheffer, I. E., Nabbout, R., Riney, K., Samia, P., Guerreiro, M., Gwer, S., Zuberi, S. M., Wilmshurst, J. M., et al. (2022) · Epilepsia · doi:10.1111/epi.17241 · Cited by 998
Self-citationHirsch, E., French, J., Scheffer, I. E., Bogacz, A., Alsaadi, T., Sperling, M. R., Abdulla, F., Zuberi, S. M., Trinka, E., Specchio, N., et al. (2022) · Epilepsia · doi:10.1111/epi.17236 · Cited by 502
Clinical utility of EEG in diagnosing and monitoring epilepsy in adults
Tatum, W. O., Rubboli, G., Kaplan, P. W., Mirsatari, S. M., Radhakrishnan, K., Gloss, D., Caboclo, L. O., Drislane, F. W., Koutroumanidis, M., Schomer, D. L., et al. (2018) · Clinical Neurophysiology · doi:10.1016/j.clinph.2018.01.019 · Cited by 314
Self-citation
Metadata
- Authors
- Kasteleijn‐Nolst Trenité, D., Rubboli, G., Hirsch, E., Martins da Silva, A., Seri, S., Wilkins, A., Parra, J., Covanis, A., Elia, M., Capovilla, G., Stephani, U., & Harding, G.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 2011-11-16
- Volume
- 53
- Issue
- 1
- Pages
- 16-24
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1564968231
- Cited by
- 229
- References
- 0
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methodology of photic stimulation revisited: Updated European algorithm for visual stimulation in the EEG laboratory. https://app.cochat.ai/papers/10.1111/j.1528-1167.2011.03319.x
- The paper
- Kasteleijn‐Nolst Trenité, D., Rubboli, G., Hirsch, E., Martins da Silva, A., Seri, S., Wilkins, A., Parra, J., Covanis, A., Elia, M., Capovilla, G., Stephani, U., & Harding, G. (2012). Methodology of photic stimulation revisited: Updated European algorithm for visual stimulation in the EEG laboratory. Epilepsia. https://doi.org/10.1111/j.1528-1167.2011.03319.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.