The Delirium Index, a Measure of the Severity of Delirium: New Findings on Reliability, Validity, and Responsiveness
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives: To assess the reliability, validity, and responsiveness of an instrument for measuring the severity of delirium, the Delirium Index (DI). Design: Prospective cohort study, with repeated patient assessments at multiple points in the hospital, at 8 weeks after discharge, and at 6 and 12 months after admission. Setting: The medical services of a primary acute‐care hospital. Participants: Medical admissions aged 65 and older: 165 with delirium and dementia, 57 with delirium only, 55 with dementia only, and 41 with neither. Measurements: Severity of delirium symptoms was measured using the DI. Delirium was diagnosed using the Confusion Assessment Method. Other measures included the Mini‐Mental State Examination, Informant Questionnaire on Cognitive Decline in the Elderly, Barthel Index (BI), premorbid instrumental activities of daily living, Charlson Comorbidity Index, Clinical Severity of Illness scale (CSI), and the Acute Physiology Score (APS). Results: The intraclass correlation coefficient of interrater reliability was 0.98. Two measures of fluctuation were significantly higher in patients with delirium than in those without delirium. At baseline, the DI was correlated with the BI, APS, and CSI in delirious patients with (correlation coefficient ( r )=−0.43, 0.17, and 0.36, respectively) or without ( r =−0.44, 0.39, 0.22, respectively) dementia. At 8 weeks, in delirious patients with and without dementia, internal responsiveness as measured by effect sizes was −0.60 and −0.74, respectively, and the standardized response mean for both groups was −0.64. Low to good levels of external responsiveness were found. Conclusion: The DI appears to be a reliable, valid, and responsive measure of the severity of delirium, in patients with delirium, with or without dementia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Inouye, S. K., Viscoli, C. M., Horwitz, R. I., Hurst, L. D., & Tinetti, M. E. (1993) · Annals of Internal Medicine · doi:10.7326/0003-4819-119-6-199309150-00005 · Cited by 854 · cited 1×
“The research nurse completed the Clinical Severity of Illness scale at the time of diagnosis of delirium, or at enrollment for those without delirium.(14,15) The score ranges from 1 (minimal) to 9 (most severe).”
Method
Cited by
The Confusion Assessment Method: A Systematic Review of Current Usage
Wei, L. A., Fearing, M. A., Sternberg, E. J., & Inouye, S. K. (2008) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2008.01674.x · Cited by 796
Assessment scales for delirium: A review
Grover, S. (2012) · World Journal of Psychiatry · doi:10.5498/wjp.v2.i4.58 · Cited by 182
A Serious Game for Clinical Assessment of Cognitive Status: Validation Study
Tong, T., Chignell, M., Tierney, M. C., & Lee, J. (2016) · JMIR Serious Games · doi:10.2196/games.5006 · Cited by 132
2- 18 F-fluoro-2-deoxyglucose positron emission tomography in delirium
Haggstrom, L. R., Nelson, J. A., Wegner, E. A., & Caplan, G. A. (2017) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x17701764 · Cited by 78
Metadata
- Authors
- McCusker, J., Cole, M. G., Dendukuri, N., & Belzile, E.
- Venue
- Journal of the American Geriatrics Society
- Publisher
- Wiley
- Published
- 2004-09-23
- Volume
- 52
- Issue
- 10
- Pages
- 1744-1749
- ISSN
- 0002-8614 (ISSN-L)
- 1532-5415
- OpenAlex
- W1492889971
- Cited by
- 132
- References
- 1
- FWCI
- 4.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.