Performance of Five Commercially Available Tooth Color‐Measuring Devices
The DOI matches its Crossref record.
Abstract
Purpose: Visual tooth color assessment is neither accurate nor precise due to various subjective and objective factors. As newly developed tooth color‐measuring devices for dental application provide the possibility of a more objective means of color determination, their performances in vitro and in vivo must be evaluated. The objective of this study was to evaluate the accuracy and precision of five commercially available tooth color‐measuring devices in standardized and in clinical environments. Materials and Methods: In an in vitro study, standards (A1, A2, A3, A3.5, and A4 shade tabs of Vita Lumin) were measured five times with five electronic devices (ShadeScan, Easyshade, Ikam, IdentaColor II, and ShadeEye) by two operators. In an in vivo study, the right upper central incisors of 25 dental students were measured with the same electronic devices by a single operator. Vita shade tab codes were expressed as CIE (International Commission on Illumination) L*a*b* values and in terms of the precision and accuracy of Δ E color differences. The Mann‐Whitney statistical test was used to analyze the differences between the two operators in the in vitro study, and the Kruskal‐Wallis one‐way analysis of variance on ranks with the post‐hoc Tukey test was used to analyze the accuracy and precision of electronic devices. Results: No statistically significant difference was found between the different operators in the in vitro study. The obtained precision was Easyshade > ShadeScan ≅ Ikam > IdentaColor II > ShadeEye. The obtained accuracy was Easyshade > ShadeScan ≅ Ikam > ShadeEye > IdentaColor II. In the in vivo study, the Easyshade and the Ikam were the most precise, and the ShadeEye and the IdentaColor II were more precise than the ShadeScan. With respect to accuracy, there was no statistical difference between the ShadeScan, Ikam, and the Easyshade. The IdentaColor II was considered inaccurate (Δ Ea= 3.4). Conclusions: In the clinical setting, the Easyshade and Ikam systems were the most reliable. The other devices tested were more reliable in vitro than in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dental color matching instruments and systems. Review of clinical and research aspects
Chu, S. J., Trushkowsky, R. D., & Paravina, R. D. (2010) · Journal of Dentistry · doi:10.1016/j.jdent.2010.07.001 · Cited by 634
Raoufi, S., & Birkhed, D. (2010) · International Dental Journal · doi:10.1016/s0020-6539(20)34254-4 · Cited by 17
Metadata
- Authors
- Dozić, A., Kleverlaan, C. J., El‐Zohairy, A., Feilzer, A. J., & Khashayar, G.
- Venue
- Journal of Prosthodontics
- Publisher
- Wiley
- Published
- 2007-03
- Volume
- 16
- Issue
- 2
- Pages
- 93-100
- ISSN
- 1059-941X (ISSN-L)
- 1532-849X
- OpenAlex
- W2133327809
- Cited by
- 227
- References
- 0
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of Five Commercially Available Tooth Color‐Measuring Devices. https://app.cochat.ai/papers/10.1111/j.1532-849x.2007.00163.x
- The paper
- Dozić, A., Kleverlaan, C. J., El‐Zohairy, A., Feilzer, A. J., & Khashayar, G. (2007). Performance of Five Commercially Available Tooth Color‐Measuring Devices. Journal of Prosthodontics. https://doi.org/10.1111/j.1532-849x.2007.00163.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.