Permanent Cardiac Pacing After Open‐heart Surgery: Acquired Heart Disease
The DOI matches its Crossref record.
Abstract
Retrospective review of 5,942 patients who underwent open‐heart surgery for acquired heart disease revealed that 123 patients (2.1%) required permanent cardiac pacing postoperatively; 4.6% of these underwent predominantly valvular surgery and 0.6% had coronary bypass. The most important factors appeared to be: 1) preoperative evidence of a conduction disorder; 2) advanced patient age; 3) dense calcium in the aortic annulus; 4) valvular surgery and, especially, tricuspid valve surgery; and 5) poor myocardial protection. Postoperative permanent pacing had a considerable impact on patient morbidity from maintenance operations; most complications were lead‐related problems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 4
- Warshawsky H., 1946, Complete heart block in calcareous aortic stenosis, Ann. Intern. Med., 27, 1040
- 10.1016/S0022-5223(19)39008-7 · doi:10.1016/s0022-5223(19)39008-7
- Poveda J., 1983, Conduction defects in aortic valve diseases after isolated aortic valve replacement, PACE, 6, A‐15
- Keefe D.L., 1983, Atrioventricular conduction abnormalities in patients undergoing aortic or mitral valve replacement, PACE, 6, A‐15
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Koplan, B. A., Stevenson, W. G., Epstein, L. M., Aranki, S. F., & Maisel, W. H. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02926-1 · Cited by 155
“will require postoperative permanent pacemaker (PPM) implantation before hospital discharge (1,2).”
BackgroundResultKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- GOLDMAN, B. S., HILL, T. J., WEISEL, R. D., SCULLY, H. E., MICKLEBOROUGH, L. L., PYM, J., & BAIRD, R. J.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1984-05
- Volume
- 7
- Issue
- 3
- Pages
- 367-371
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2006283708
- Cited by
- 64
- References
- 0
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Permanent Cardiac Pacing After Open‐heart Surgery: Acquired Heart Disease. https://app.cochat.ai/papers/10.1111/j.1540-8159.1984.tb04919.x
- The paper
- GOLDMAN, B. S., HILL, T. J., WEISEL, R. D., SCULLY, H. E., MICKLEBOROUGH, L. L., PYM, J., & BAIRD, R. J. (1984). Permanent Cardiac Pacing After Open‐heart Surgery: Acquired Heart Disease. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1984.tb04919.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).