Use of Atrial Pacing in a Young Population
The DOI matches its Crossref record.
Abstract
Forty pediatric and young aduit patients (1–20 years; mean, 11 years of age) had implanlation of atrial demand (AAI) pacemakers over a 5.5 year period. Nineteen were impllinted by epicardial technique and 21 transvcnously. Standard lithium single chamber pulse generators and standard atriai leads were used. Operative stimulation thresholds were better for transivenous leads than for epicardial (0.75 volts vs. 1.5 volls at 0.5 ms) (p < 0.05). Pulse width thresholds at a mean of 1.5 years were not significantly different (0.11 ms for transvenous vs. 0.1 8 for epicardial). No patient developed AV block. Eight patients (four epicardial and four endocardial) required reoperation during the mean 3.5 year follow‐up—four because of lead problems and four because of persistent tachycardia. Of the six patients who received an automatic antitachycardia pacemaker, only one had persistent symptoms while seven of eight who received a standard unit continued to have symptoms. Twenty‐eight of 29 symptomatic patients without tachycardia became asymptomatic. Atrial pacing appears to be a safe and effective therapy for children with sick sinus syndrome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.1016/S0735-1097(83)80147-8 · DOI
- 10.1016/0002-8703(82)90273-3 · doi:10.1016/0002-8703(82)90273-3
- 10.1161/01.CIR.59.6.1266 · doi:10.1161/01.cir.59.6.1266
- 10.1016/0002-9149(80)90482-8 · doi:10.1016/0002-9149(80)90482-8
- 10.1016/0002-8703(83)90250-8 · doi:10.1016/0002-8703(83)90250-8
- Ott D.A., 1982, Atrial pacing via the subxyphoid approach, Texus Heart Institute., 9, 149
- 10.1016/0002-8703(81)90044-2 · doi:10.1016/0002-8703(81)90044-2
- 10.1111/j.1540-8159.1984.tb04887.x · DOI
- Ayes H, 1983, Stability of AV conduction in patients with implanted atrial pacemakers, Am. Heart J., 107, 644, 10.1016/0002-8703(84)90309-0 · DOI
- 10.1016/0002-8703(83)90060-1 · doi:10.1016/0002-8703(83)90060-1
- Wampler D.G., 1983, Cardiac pacing in children and young adults, Am. J. Dis. Child., 137, 1098
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
The Natural History of Sick Sinus Syndrome: Sick Sinus Syndrome‐Histoire Naturelle
SUTTON, R., & KENNY, R. (1986) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1986.tb06678.x · Cited by 288
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Metadata
- Authors
- GILLETTE, P. C., WAMPLER, D. G., SHANNON, C., & OTT, D.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1985-01
- Volume
- 8
- Issue
- 1
- Pages
- 94-100
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W1968082644
- Cited by
- 35
- References
- 0
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Atrial Pacing in a Young Population. https://app.cochat.ai/papers/10.1111/j.1540-8159.1985.tb05728.x
- The paper
- GILLETTE, P. C., WAMPLER, D. G., SHANNON, C., & OTT, D. (1985). Use of Atrial Pacing in a Young Population. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1985.tb05728.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.