Ablation of a Left‐Sided Free‐Wall Accessory Pathway by Percutaneous Catheter Application of Radiofrequency Current in a Patient with the Wolff‐Parkinson‐White Syndrome
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
KUCK, K‐H., et al.: Ablation of a Left‐Sided Free‐Wall Accessory Pathway by Percutaneous Catheter Application of Radiofrequency Current in a Patient with the Wolff‐Parkinson‐White Syndrome A case is presented of a 20‐year‐old woman with a history of three episodes of syncope within the last 4 years, which was caused by a rapid ventricular response to atrial fibrillation via a left‐sided posterior accessory pathway. A variety of antiarrhythmic agents had failed to control the arrhythmia. Using a novel dual catheter approach, with one catheter in the coronary sinus and an adjacent catheter in the left ventricle close to the mitral annulus, accessory pathway conduction was successfully interrupted by two radiofrequency current applications between the tip electrodes of the two catheters. During follow‐up, 12‐lead electrocardiogroms have been normal and the patient has been asymptomatic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ventricular fibrillation in the Wolff-Parkinson-White syndrome
Klein, G. J., Bashore, T. M., Sellers, T. D., Pritchett, E. L. C., Smith, W. M., & Gallagher, J. J. (1979) · New England Journal of Medicine · doi:10.1056/nejm197911153012003 · Cited by 830
Cited by
Jackman, W. M., Wang, X., Friday, K. J., Roman, C. A., Moulton, K. P., Beckman, K. J., McClelland, J. H., Twidale, N., Hazlitt, H. A., Prior, M. I., et al. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242301 · Cited by 1,422
Self-citationCalkins, H., Sousa, J., El-Atassi, R., Rosenheck, S., de Buitleir, M., Kou, W. H., Kadish, A. H., Langberg, J. J., & Morady, F. (1991) · New England Journal of Medicine · doi:10.1056/nejm199106063242302 · Cited by 698
Calkins, H., Langberg, J., Sousa, J., el-Atassi, R., Leon, A., Kou, W., Kalbfleisch, S., & Morady, F. (1992) · Circulation · doi:10.1161/01.cir.85.4.1337 · Cited by 399
Radiofrequency current catheter ablation of accessory atrioventricular pathways
Kuck, K.-H., Schluter, M., Geiger, M., Siebels, J., & Duckeck, W. (1991) · The Lancet · doi:10.1016/0140-6736(91)93258-b · Cited by 363
Self-citationLesh, M. D., Van Hare, G. F., Schamp, D. J., Chien, W., Lee, M. A., Griffin, J. C., Langberg, J. J., Cohen, T. J., Lurie, K. G., & Scheinman, M. M. (1992) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(92)90338-n · Cited by 306
Metadata
- Authors
- KUCK, K., KUNZE, K., SCHLÜTER, M., GEICER, M., & JACKMAN, W. M.
- Venue
- Pacing and Clinical Electrophysiology
- Publisher
- Wiley
- Published
- 1989-10
- Volume
- 12
- Issue
- 10
- Pages
- 1681-1690
- ISSN
- 0147-8389 (ISSN-L)
- 1540-8159
- OpenAlex
- W2043823575
- Cited by
- 51
- References
- 1
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ablation of a Left‐Sided Free‐Wall Accessory Pathway by Percutaneous Catheter Application of Radiofrequency Current in a Patient with the Wolff‐Parkinson‐White Syndrome. https://app.cochat.ai/papers/10.1111/j.1540-8159.1989.tb01847.x
- The paper
- KUCK, K., KUNZE, K., SCHLÜTER, M., GEICER, M., & JACKMAN, W. M. (1989). Ablation of a Left‐Sided Free‐Wall Accessory Pathway by Percutaneous Catheter Application of Radiofrequency Current in a Patient with the Wolff‐Parkinson‐White Syndrome. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.1989.tb01847.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.